De-Installation; Machine Use - Rivacold FS Série Mode D'emploi Et D'entretien

Masquer les pouces Voir aussi pour FS Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

external surfaces resistant to atmospheric agents;
protected against access to unauthorised people;
with the following environmental conditions:
good ventilation;
room temperature between -20 °C and +50 °C;
relative humidity of compressed air 30% and 80%;
possibly in dry, dust-free atmosphere.
ATTENTION:

4.4.1. De-installation

If the machine must be de-installed, proceed following the inverse order for installation reported in Paragraph 4.3 - Installation.
DANGER:
To conduct the task in question, the following Individual Protection Devices are necessary:
5
.
M
a
c
h
i
n
e
5
.
M
a
c
h
i
n
e

5.1. Machine use

DANGER:
To use the machine, the following Individual Protection Devices are necessary:
5.1.1. Operation
Before starting the machine, it is necessary to ensure:
the locking screws are tight;
the electrical connections were correctly installed;
the coldroom door is closed to ensure the micro-door contact is closed.
5.1.2. Switch on/off
To turn on (off) the machine, the "ON/OFF" button on the control panel must be pressed for more than 5 seconds.
ATTENTION:
5.1.3. Parameter variation procedure
Functioning of the Blocksystem series FS is regulated by the parameters set in the memory of the electronic central unit by the
manufacturer (see Table 6). We recommend you do not change these values unless strictly necessary and in any case always contact
the enabled staff. As well as for functioning, the parameters are sub-divided by safety/accessibility level:
level 0
SETPOINT parameters
level 1
frequent use parameters
The parameters can be changed on the keyboard, via the LAN (Master/Slave) network or using the Supervision network.
do not remove any packaging possibly present for certain components of the machine and take adequate
precautions to protect the exposed parts.
the manufacturer declines all responsibility for any damage to property and/or persons deriving from
improper interventions conducted by unqualified, untrained or unauthorised staff.
u
s
e
u
s
e
for the machine, only operators correctly training and informed on the risks present can intervene on the
machine and only having fully read this use and maintenance handbook. the manufacturer declines all
responsibility for any damage to property and/or persons deriving from improper interventions conducted
by unqualified, untrained or unauthorised staff.
when the machine is first turned on, the word OFF shows on the control panel, alternating with the
cell temperature.
direct access (see Paragraph 5.1.3.1);
access without password (see Paragraph 5.1.3.2).
UK
FS Pag. 50 Rev 00 02/12

Publicité

Table des Matières
loading

Table des Matières