Malfunction
Green "SYNC" Led on the
receiver column out
BIRIS II 100 & 200 only
Green "Tr ON" Led on the
transmitter column out
Red "Alarm" Led on the receiver
column out continually
BIRIS II 50 only
Orange "Disq." Led on the
receiver column out continually
BIRIS II 100 & 200 only
Red "Alarm" Led on the receiver
column lit continually
BIRIS II 50 only
Red "Alarm" Led on the receiver
column does not light up when
the beams are interrupted
Malfunction
Rx MASTER
Green Led blinking
Continual alarm:
Orange Led continually
lit after one minute
3 Leds out
Green Led set
Continual alarm:
Orange Led continually
lit after one minute
Tx MASTER
Green Led blinking
Green Led out
Green Led blinking
Probable cause
Improper power supply
−
Transmitter column without
−
power
Transmission module and
−
reception module on
different channels
Poor alignment of cells
−
Object obstructing the beams
−
The two cells are not
−
interrupted simultaneously (in
mode "AND")
Mode " SYNCHRO " for BIRIS II 100 & 200 only
Rx SLAVE
Green Led blinking
Red and orange Leds
out
3 Leds out
Green Led blinking
Green Led blinking
Tx SLAVE
Green Led blinking
Green Led blinking
Green Led out
Probable cause
2 modules configured in
−
master or slave mode
Synchro link interrupted
−
Slave without power
−
Master without power
−
Master transmitter column
−
without power
Master transmitter module
−
and master receiver
module on different
channels
Object obstructing the
−
beams
2 modules configured in
−
master or slave mode
Synchro link interrupted
−
Master without power
−
Slave without power
−
- 30 -
BIRIS II 50/100/200
Solution
Check power supply
−
Check transmitter power supply
−
Put the transmitter and receiver
−
Re-perform the alignment
−
procedure
Disengage the beam axes
−
Interrupt all beams
−
simultaneously
Solution
Reconfigure the modules
−
Establish the synchro link
−
Provide power to the slave
−
module
Provide power to the
−
master module
Check transmitter power
−
supply.
Put the transmitter and
−
receiver on the same
channel.
Disengage the beam axes.
−
Reconfigure the modules
−
Establish the synchro link
−
Provide power to the
−
master module
Provide power to the slave
−
module