Mode " AND "
Simultaneous
interruption of 2 cells
for intrusion alarm.
Adjusting response
time of the intrusion
alarm :
50ms
to
700ms
Attention : Adjust the response time using the provided potentiometer.
In mode " SYNCHRO " the potentiometer for the master receiver column (RX) allows adjustment of
the response time for the intrusion alarm. That of the slave receiver column allows selection or not
of the interruption of the bottom cell during the fixed response time of 1.5 s to trigger the intrusion
alarm.
Potentiometer turned all the way clockwise :
bottom cell detection enable.
ALIGN. CHANNEL
1
2
3
4
ON
OFF
Description of operating modes
Mode " OR "
Interruption of one of
the 2 cells for
intrusion alarm.
Adjusting response
time of the intrusion
alarm :
100ms
to
700ms
ALIGN. CHANNEL
1
2
3
4
ON
OFF
DELAY
RX
50
700
ms
SLAVE
Mode " AND/OR "
Simultaneous
interruption of 2 cells
for intrusion alarm.
Interruption of the
bottom cell for a
minimum of 1.5 s for
intrusion alarm.
Response time
Adjusting response
time of the intrusion
alarm :
100ms
700ms
Fixed response time for
the bottom cell set at
1.5 s .
MASTER
DELAY
RX
50
ms
Potentiometer for intrusion
alarm response time
Potentiometer turned all the way counter-
clockwise : bottom cell detection disable.
ALIGN. CHANNEL
MODE
5
6
1
2
3
ON
OFF
- 27 -
BIRIS II 50/100/200
Mode " SYNCHRO "
4
3
2
MASTER
1
Simultaneous
interruption of 2 adjacent
cells for intrusion alarm.
Interruption of the
bottom cell of the master
barrier for a minimum of
1.5 s for intrusion alarm.
Adjusting response time
of the intrusion alarm :
50ms
to
Fixed response time for
the bottom cell set at 1.5
s .
MODE
5
6
ON
OFF
700
RX
4
ON
OFF
SLAVE
SLAVE
to
700ms
DELAY
MODE
5
6
ON
OFF
50
700
ms