4.3.2. Setting the cycle time

The cycle time is set at the factory to 60 seconds. If necessary, this can be adjusted using the red dip switch element
on the display card (item 2, Fig. 8) from 7.5 - 120 sec. (Table inside the control box). Once the machine has been
restarted (connected to the power supply), the changes will take effect and will be briefly shown on the display.
4.3.3. Explanation of display symbols and LEDs
There are 2 LEDs on the control card
Designation
DL1
DL2

5. Periodic maintenance and cleaning

The machine must only be operated in a fault-free condition! You must shut down the machine
immediately if you discover any damage or malfunction!
Caution!
Risk of physical injury to people and animals and material damage!
• only perform maintenance and cleaning work when the machine is switched off. Disconnect the mains plug!!
• maintenance and cleaning work must only be carried out by trained personnel
• illegible or damaged stickers (e.g. type plate) must be replaced immediately with new ones.

5.1. Overview of maintenance schedule:

Component
Visual inspection of mechanical + electrical safety
technology

Gears

Screw connections
Moving parts
(pendulum bearings, brush bearings)
Brushes
Entire machine

5.2. Visual inspection of mechanical + electrical safety technology:

• daily inspection of the machine for externally visible damage and general functionality.
• check of the status of the electrical cables and the control box. (bite marks, wear spots, loose connections, etc.).
Repair work on electrical components must only be carried out by a qualified electrician taking account of
electrical safety regulations.
• disconnect the power, e.g. via the fuse
• secure against power reconnection
• check voltage-free state
• earthing and short-circuits
• cover and separate neighbouring parts that are carrying voltage
5.3. Gears
The gap between the brushes and the gears and the seals in each case must be checked weekly for soiling (hair!)
and cleaned where necessary. If cleaning is not carried out promptly, hair can be pulled / pressed into the seals,
Colour
Red, flashing
Mains voltage present / brush ready for operation
Red, lights up
Fuse faulty / replace fuse
Description
Cleaning
Lubrication
X
X
X
44
Inspection
X
X
X
X
X
X
Frequency
Daily
Weekly
Weekly
Weekly
Weekly
Quarterly