• Chose a suitable wall where the high pressure water cleaner can be mounted: the high
pressure water cleaner must be mounted exclusively on brick walls or reinforced cement
walls with thickness of no less than 10 cm/4"; do not mount the high pressure water cleaner
on walls made of plasterboard, wood, sheet metal or any other material that is not suitable
to take the wall-plugs supplied.
• To mount on the wall, use exclusively the kit supplied (bracket, screws, wall-plugs and
nuts): if any part of the kit is lost or damaged during installation, contact your dealer to
have it replaced.
• Rest the bracket (11) against the wall and trace two marks with a pencil through the holes
F (
) that will act as a reference for drilling the holes: position the frame roughly at
See FIG. 1
the height of your shoulders to ensure ease of use.
• Using a 10 mm/0.4" bit (not supplied), suitable for drilling brick/reinforced cement walls,
drill two holes, approximately 8-9 cm/3.2-3.5" in depth where the holes were marked
earlier. When drilling the holes, pay attention to the safety warnings given in the use
and maintenance manual of the drill used. Also remember to make sure no pipes and/or
electrical cables run through the wall where you drill the holes.
• Put the wall-plugs (14) in the holes, making sure their necks are flush with the wall: do not
push the wall-plugs too far into the wall and do not leave them protruding from it either.
• Using a 5 mm/0.2" fixed jaw spanner (not supplied), screw the screws (9) until the threaded
part enters the wall-plug completely.
• Put the rubber rings (10) in the safety hooks (3) and (7), and then put the hooks in the wall
bracket (11). Make sure the hook (3) is inserted on the left and the (7) on the right.
5-B and 5-C.
• Put the bracket (11) in the screws protruding from the wall and secure it with the nuts (16).
While doing this, make sure the screws (9) enter the hole F of the bracket and the special
slot in the hooks
• (3) and (7). Before you tighten the nuts permanently (16), using a 13 mm/0.5" fixed jaw
spanner (not supplied), make sure the hooks (3) and (7) are raised.
• Make sure the wall bracket is fitted firmly: do not hang on the bracket with your own
weight to check it.
• Make sure the release button (8) is released, by pushing it inwards; raise the high pressure
water cleaner safely and fit the bottom guide in the bracket (11), until the button clicks
(8).
See FIG. 5-D.
• Lower the hooks (3) and (7), so that they couple in the cowling of the high pressure water
cleaner.
See FIGS. 5-E and 5-F.
• Feed the power supply cable (6) within the relative guide.
• If you wish, you can also install the wall-mounted accessory frame (13), exploiting the
screws (36) and the wall-plugs (37w) supplied. To drill, use a 6 mm/0.24" bit (not supplied),
making three holes, approximately 4-5 cm/1.6-2.0" in depth by marks made as previously
described for the wall-mounted frame. Use a suitable Philips screwdriver to tighten the
screws (not supplied).
DEMOUNTING FROM THE WALL – INSTALLING ON THE FLOOR
• Unscrew the fitting (25) and remove the filter and gasket.
in a safe place because it will be used again when the high pressure water cleaner is put
back on the wall.
• Put the filter (18) in the water inlet fitting (17). Put the gasket (26) in the curved hose holder
(27) and screw it to the fitting (17).
17
INSTALLATION – WALL MOUNTING
See FIG. 5-A.
See FIG. 6.
See FIG. 1.
See FIG. 5-G.
See FIG. 1.
The installation of the curved suction fitting
See FIG.
See FIG. 5-B and 5-C.
Put the fitting away