Problem
Appliance does not
work.
Appliance cools too
much.
The food is too warm.
Interior lighting does
not work.
Heavy build-up of
frost, possibly also on
the door seal.
Unusual noises.
The compressor does
not start immediately
after changing the
temperature setting.
Water on the floor or
storage shelves.
Possible cause
Appliance is not switched on.
Main plug is not plugged in or
is loose.
Fuse has blown or is defective.
Outlet is defective.
Temperature is set too cold.
Temperature is not properly
adjusted.
Door was open for an
extended period.
A large quantity of warm food
was placed in the appliance
within the last 24 hours.
The appliance is near a heat
source.
Light bulb is defective.
Door seal is not air-tight
(possibly after reversing the
door).
Appliance is not level.
The appliance is touching the
wall or other objects.
A component, e.g. a pipe, on
the rear of the appliance is
touching another part of the
appliance or the wall.
This is normal, no error has
occurred.
Water drain hole is blocked.
Solution
Switch on the appliance.
Plug the appliance into the
electrical socket.
Check fuse, replace if necessary.
Defective parts need to be
repaired by an electrician.
Turn the temperature regulator to
a warmer setting temporarily.
Please
refer to
section.
Open the door only as long as
necessary.
Turn the temperature regulation
to a colder setting temporarily.
Please
refer to
location" section.
Please look in the "changing the
Light Bulb "section.
Car efully war m the leaking
sections of the door seal with a
hair dryer (on a cool setting). At
the same time, shape the warmed
door seal by hand so that it sits
correctly.
Readjust the feet.
Move the appliance slightly.
If necessary, carefully bend the
component out of the way.
The compressor starts after a
period of time.
refer to the "Cleaning and care"
section.
12
the "Initial Start Up"
the "Installation