INSTALLATION
Installing HDW-XB, HDW-XBN, and
HDW-XBR Models
HDW-XB, HDW-XBN, and HDW-XBR models are built-in units
that require installation into a cabinet before operation.
WARNING
ELECTRIC SHOCK HAzARD: Built-in units must be
installed by a qualified electrician. Installation must
conform to all local electrical codes. Installation by
unqualified personnel will void the unit warranty and may
lead to electric shock or burn, as well as damage to unit
and/or its surroundings.
1. Cut the appropriate opening in the cabinet. Refer to the
"Built-In Cutout Dimensions" chart and illustration for
dimensions.
NOTE: Maintain a minimum clearance of 25 mm (1") between
the cutout opening and the floor.
2. Fasten a locking strip (not supplied) to the lower front
inside lip of the cabinet opening.
Front View
A
C
Locking
Strip
25 mm
(1")
Locking
Strip
3 mm
(1/8")
22 mm
(7/8")
Cutout and Locking Strip Dimensions
3. Make sure a properly grounded electrical supply of the
correct voltage and size is installed inside the cabinet
cutout. See the SPECIFICaTIONS section for details.
4. Partially insert the unit into the opening, making sure the
conduit is fed into the opening first.
5. Have a qualified electrician connect the unit wires from the
conduit to the electrical supply inside the cabinet.
6. Before installing the unit into the opening completely, apply
a bead of National Sanitation Foundation-approved
sealant between the heated drawer flange and the cabinet
facing.
7. Slide the unit into the opening until the front locking studs
drop behind the locking strip. To verify installation, pull out
the bottom drawer completely and gently pull to ensure the
unit is locked in place.
Side View
Built-In Cutout Dimensions
B
HDW-1BN
HDW-2BN
HDW-3BN
HDW-1BR
HDW-2BR
HDW-3BR
10
Cabinet
Facing
Heated
Drawer
Flange
Built-In Installation (HDW-2B Model shown)
Width
Model
(A)
HDW-1B
720 mm
(28-3/8 '' )
HDW-2B
720 mm
(28-3/8 '' )
HDW-3B
720 mm
(28-3/8 '' )
502 mm
(19-3/4 '' )
502 mm
(19-3/4 '' )
502 mm
(19-3/4 '' )
722 mm
(28-7/16 '' )
722 mm
(28-7/16 '' )
722 mm
(28-7/16 '' )
Locking
Strip
Locking Studs
(underneath)
Depth
Height
(B)
(C)
610 mm
257 mm
(24 '' )
(10-1/8 '' )
610 mm
514 mm
(24 '' )
(20-1/4 '' )
610 mm
771 mm
(24 '' )
(30-3/8 '' )
720 mm
257 mm
(28-3/8 '' )
(10-1/8 '' )
720 mm
514 mm
(28-3/8 '' )
(20-1/4 '' )
720 mm
771 mm
(28-3/8 '' )
(30-3/8 '' )
460 mm
257 mm
(18-1/8 '' )
(10-1/8 '' )
460 mm
529 mm
(18-1/8 '' )
(20-13/16 '' )
460 mm
802 mm
(18-1/8 '' )
(31-9/16 '' )