TYPE 2 :
CONNECTION ON
THE RIGHT HAND
SIDE
5) Programming
The device can be controlled remotely if its pilot wire is connected to a device fitted with a programmer,
a programming unit or an energy management unit.
Chart indicating the orders the device can receive over its pilot wire
Orders received Current absent
Ref/neutral
oscilloscope
Mode achieved
Heating
temperature
1) Description of the lower part of the device.
A: Switch to control the heating resistor incorporated in the device.
B: Indicator light to check the operating status of your device.
C: Supply tap to allow inlet of hot water from the central heating.This can be thermostatically controlled
or not depending on your choice.
D: Boiler return tap to allow the hot water to leave the central heating.
E: Lower cover.
(to be measured between the pilot wire and the neutral).
CONFORT
CONFORT
setting
U
SING THE DEVICE
CASE OF THE MIXED VERSIONS WITH FAN
Téléchargé sur www.confort-electrique.fr
Negative half-
Full alternance
alternance
230V
-115V
ECO
STANDBY
3°C to 4°C
Standby
below
temperature,
CONFORT
about 7°C
setting
{
Positive half-
alternance
+115V
STOP LOAD
SHEDDING
Instant device
stop. Can also
be used for load
shedding.