Switched socket outlet 7075.12 (6)
This unit has been designed for an ohmic load of up
to 1,800 Watt at 230 V (900 W at 115 V), and has
been secured by an 8 A fuse. Inductive loads (such
as transformers, pumps, ozone producers) can be
connected up to about 900 W (230 V). The fuse is
located in the switched socket outlet (the fuse may
be replaced by an electrician only).
TIMER function 7075/2
As long as the actual value is below the setpoint
value set, the unit will continue metering. The
metering time timer fitted will interrupt the metering
action for better mixture or for protection against
overdosage. The adjusting wheel (7) can be used
for the adjustment, permitting a metering time from
5 to 15 minutes or continuous metering (OFF). The
interruption after the metering time will last between
5 and 15 minutes depending on the time set.
Prise commandée 7075.12 (6)
Elle est conçue pour une charge résistive de
1800W en 230V (900W en 115V) et protégée par
un fusible de 8A. Les charges inductives (par ex.
transformateurs, pompes, générateurs d'ozone)
peuvent être raccordées à hauteur de 900W
(230V). Le fusible se trouve à l'intérieur de la prise
(remplacement uniquement par un professionnel
en électricité).

Fonction TIMER 7075/2

Le dosage en ozone s'effectue tant que la mesure
mV se situe en-dessous de la consigne. Le timer
intégré permet une interruption du dosage pour un
meilleur mélange ou pour éviter tout surdosage.
Son réglage s'effectue par le bouton (7). Il est ainsi
possible d'appliquer un temps de dosage de 5 à
15 min ou un dosage permanent (position OFF).
De même, la durée de l'interruption de dosage en
ozone est variable de 5 à 15 min en fonction du
temps de dosage.