Function Test; Electrical Connection - Truma Duomatic L Plus DE Mode D'emploi / Instructions De Montage

Détendeurs de gaz
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1. Figure A: Connect central
regulator „A" and changeover
regulator „B" to gas bottles
with protective caps on top if
possible (anticlockwise
thread!) - Always connect
by hand, do not use tools!
2. Screw existing gas hose (3)
to central regulator „A".
3. Screw connecting hose (4)
to regulators „A" and „B".
An extension kit (Art.
no. 50020-26900) is
available from Truma as a
special accessory for con-
necting regulators „A" and
„B" where the cylinders are
more than 65 cm apart.
4. Attach regulator bracket
(14) to wall of vehicle in a
suitable position.
5. Drill hole Ø 15 mm for ca-
ble leadthrough (min. 50 cm
above bottom of cylinder
box) to interior.
6. Lead regulator connecting
cable (5) through hole (6)
and attach in cylinder box
using clamps. Use rubber
grommet or body sealant for
leadthrough (6).
8
The connection to
the connecting cable
must not be in the cylinder
box!
The connecting cable to
the changeover regula-
tor „B" has an additional
1.5 m of cable, which is re-
quired to connect external
33 kg gas cylinders.
7. Figure B: Make room for
control panel (7) in clearly
visible position (connecting
cable length 6 m) and drill
Ø 55 mm hole.
A surface-type frame
(8 - Art. no. 40000-
52600 and a 5 m extension
Art. no. 34300-01 for the con-
necting cable (9) are available
for the control panel (7) as
accessories. Side panels (11)
in different colours are avail-
able for finishing off the cov-
ering frame (10).
8. Attach connecting cable
(9) to control panel (7) and
then put rear covering cap on
(12) as a strain reliever.
9. Lead cable (9) towards rear
through hole and lead accord-
ingly to gas cylinder box and
12 V central electrical system.
10. Attach control panel (7)
using 4 screws (13) and fit
covering frame (10).
11. Attach connecting cable
(9) to regulator connecting
cables (5) outside cylinder
box (black to black and white
to white).
Electrical
connection 12 V
Protect 12 V lead (15)
using provided 1 A
fuse (16). (Fuse not included
in scope of delivery of large
industrial box!)
Red = Plus
Blue = Minus

Function Test

After installation, the tight-
ness of the Duomatic L Plus
must be checked using suit-
able leak-finding equipment.
The rest of the gas system
must be tested using the
pressure drop method.
Any test certificate that is
available (mandatory in
Germany in accordance with
DVGW worksheet G 607, for
example!) must be updated
accordingly.
Then check all equipment
functions as described in the
operating instructions.
The operating instructions
must be handed to the
operator!