PROGRAMMING PROCEDURE (Setting the programmer and the current sensor)
• The installation of both anti-derailment buffers is absolutely obligatory before starting programming.
• Make sure the safety devices are at rest and the ECU is receiving mains power otherwise you will not be able to enter programming.
• Choose the type of geared motor you are using from the "display menu" (page 21).
• The system automatically sets itself to work with one or two gate leaves.
Dip-switch settings DS1
CAUTION:
If you change the dip settings you must memorise them; press the
"PROG" button, "dIP" will appear on the display indicating that the settings have
been memorised.
Sequential command TD/CH1
Dip 1 "ON" = Sequential command "open-close"
Travel direction inversion only during closing.
Dip 1 "OFF" = Sequential command "open-block-close-block"
Automatic reclosing (DIP 2)
Dip 2 "ON" = Automatic reclosing enabled
Dip 2 "OFF" = Automatic reclosing disabled
Pre-flashing (DIP 3)
Dip 3 "ON" = Pre-flashing activated
Dip 3 "OFF" = Pre-flashing excluded
Warning light output (DIP 4)
Dip 4 "ON" = Warning light output intermittent
Dip 4 "OFF" = Warning light output fixed
Indicator light (DIP 5)
Dip 5 "ON" = Indicator light intermittent
Dip 5 "OFF" = Indicator light fixed
*
The indicator light flashes slowly during opening, rapidly during closing; remains
lit when the gate is blocked but not completely closed and is off when the gate
is completely closed.
FTCI mode (DIP 6)
Dip 6 "ON" = FTCI also active when the gate is blocked
If the photocells are in alarm and the gate is blocked, no movement commands
will be accepted (even opening commands).
Dip 6 "OFF" = FTCI active only during closing
In both cases activating the FTCI safety device during the closing stage will force
travel direction inversion.
FTCI test (DIP 7)
Dip 7 "ON" = FTCI test enabled
Dip 7 "OFF" = FTCI test disabled
If you enable the security test you will have to connect both the transmitter and
the receiver to the controlled load output (CTRL 30 Vdc). When the test is enabled
one second will pass between receiving a command and carrying it out.
FTCS test (DIP 8)
Dip 8 "ON" = FTCS test enabled
Dip 8 "OFF" = FTCS test disabled
If you enable the security test you will have to connect both the transmitter and
the receiver to the controlled load output (CTRL 30 Vdc). When the test is enabled
one second will pass between receiving a command and carrying it out.
Opening direction gate delay (DIP 9)
Dip 9 "ON" = Opening direction gate delay enabled
Dip 9 "OFF" = Opening direction gate delay disabled
If you enable gate delay the following will occur: during the opening movement gate
leaf 1 moves first and then gate leaf 2. In the closing direction gate leaf
first then gate leaf 1. If gate delay is disabled both gate leaves move simultaneously.
Electric lock (DIP 10)
Dip 10 "ON" = Electric lock enabled
Dip 10 "OFF" = Electric lock disabled
If the electric lock is enabled the ELS output (binding post 8) will be activated
before gate leaf 1 moves and will remain active until gate leaf one has moved a
few centimetres.
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
*
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
2
moves
ON
1 2 3 4 5 6 7 8 9 10
PRESS THE PROG BUTTON FOR MORE
THAN 4 SECONDS: THE "PAUSE" SYMBOL
WILL APPEAR INDICATING THAT YOU ARE
IN THE PAUSE PROGRAMMING MODE
ATTENTION! IF THE GATE MOVES
IN THE CLOSING DIRECTION THE
MOTOR CONNECTION IS
INCORRECT. PRESS "PROG"
AGAIN TO CANCEL THE
PROGRAMMING PROCEDURE,
INVERT THE MOTOR
CONNECTION (RED AND BLACK
CABLE) AND REPEAT THE
PROGRAMMING PROCEDURE.
WHEN THE GATES REACH THE COMPLETELY OPEN POSITION THEY INVERT THE TRAVEL
DIRECTION AND AFTER MOVING FOR A FEW CENTIMETRES THEY WILL OPEN AGAIN TO
CONFIRM THE COMPLETELY OPEN POSITION. AT THIS POINT THE LEAVES MOVE ONE AT A
TIME IN THE CLOSING DIRECTION (FIRST GATE LEAF 2). WHEN ONE OF THE GATE LEAVES
REACHES THE COMPLETELY CLOSED POSITION IT INVERTS THE TRAVEL DIRECTION AND
AFTER MOVING FOR A FEW CENTIMETRES IT WILL CLOSE AGAIN TO CONFIRM THE
COMPLETELY CLOSED POSITION.
AFTER HAVING CARRIED OUT THIS MANOEUVRE THE LOGIC CONTROL WILL OPEN THEN
CLOSE THE GATE LEAVES COMPLETELY IN ORDER TO CALIBRATE THE CURRENT SENSOR.
THE OPERATION HAS NOT
SUCCEEDED. YOU WILL HAVE
TO REPEAT THE
PROGRAMMING PROCEDURE.
CURRENT SENSOR
The programmer checks the electrical input to the motor, detecting any eventual
increase in effort above the normal operating limits and intervenes as an additional safety
device. If the sensor intervenes during the opening direction the gate inverts the travel
direction immediately and proceeds to the fully open position. If the sensor intervenes
during the closing direction the gate automatically inverts the travel direction of a few
centimetres and then stops to free the obstacle. If automatic reclosing is enabled the
gate will reclose after the pause time has elapsed.
Repositioning
Attention! During the repositioning manoeuvre the current sensor value "SnS" could
be different leading to a momentary increase in the door impact force. At the end of
the manoeuvre, however, it will reset automatically to the chosen value.
If the programmer blocks due to an encoder count error
reset
, when one of the motors has been released
with one of the motors
taneously for 2 seconds and will then switch off for 10 seconds.
If in this stage you send a (TA, TC, TAL or TD) command to the programmer. The
programmer will move the gates slowly to the completely closed position (2 times as
in the programming procedure) in order to recover the correct position. At this point the
programmer will function normally. If a "TA" command is given the positioning recovery
is carried out in the opening direction.
No commands will be accepted during repositioning but the security devices will cut
in and block all movement if they go into alarm.
To interrupt the repositioning manoeuvre press the "PROG" or "TB" button.
20
PRESS PROG
THE PAUSE TIME COUNT
WILL START (MIN. 2
SECONDS: MAX 120
SECONDS) INDICATED BY
THE "PAUSE" SYMBOL
FLASHING ON THE DISPLAY
PRESS PROG
THE PAUSE TIME COUNT
ENDS AND THE DOOR OPENS
SLOWLY IN ORDER TO FIND
THE COMPLETELY OPEN
POSITION.
WHEN THE GATE REACHES THE
COMPLETELY CLOSED POSITION THE
PROGRAMMER SAVES THE PARAMETERS
AND QUITS THE PROGRAMMING MODE
, after a programmer
or there is a problem
the warning lights and indicator light will flash simul-
1...4... sec.