To attenuate any vibrations, "silent-blocks" can be inserted under the feet of the machine before is it fixed in position.
(must be purchased separately).
The support should be very slightly sloped (a slope of 1 to 2% will suffice) towards the corner where the condensate
drainage hole is situated.
The condensate drain union is enclosed with the heat pump. It comprises a set of 6 plugs* one of which is perforated.
* 1 cap for BWT MPI 100 heat pumps and 6 caps for BWT MPI 160 to 380 heat pumps.
Perforated plug, ref 1
Over time, the volume of condensates generated can be considerable if the air is humid. Water should never be
allowed to accumulate around the machine: if the condensates will not be absorbed or evacuated by the terrain, a
drain must be created.
Similarly, precipitation (rain, snow) and piles of dead leaves should not be allowed to accumulate under the machine
to the point where there reach the base of the machine: choose the site carefully and ensure that the support provides
enough elevation off the ground to prevent this risk in most situations.
To prevent water from accumulating on the evaporator and freezing during cold, wet weather, an awning may be
erected over the machine, ensure that there is a gap of at least 50 cm between the top of the machine and the canopy.
34/96
2020/11 - Indice de révision : I - Code : 33340
Non perforated plug, ref 2
BWT MPI100
The plugs should be
inserted in the holes in
the base of the machine,
see the figure opposite.
Note that the perforated
plug (ref 1) should be
located at the lowest
point
condensates to drain
properly.
BWT MPI160
to BWT MPI380
CHAUFFAGE & DÉSHUMIDIFICATION
to
allow
the