Connecting The Converter; Connecting The Connection Cable - Dometic PerfectCharge DC 08 Instructions De Montage Et De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36

Connecting the converter

7
Connecting the converter
7.1
Connecting the input battery
!
WARNING!
Do not reverse the polarity. Reverse polarity of the battery connections
can cause injury and irreversably damage the device.
A
NOTICE!
Tighten the nuts or bolts to a torque of 12 – 13 Nm. Loose connections
may cause overheating.
➤ Set the main switch (fig. 1 6, page 3) to "0".
➤ Lay the positive cable (red) (fig. 1 7, page 3) from the converter to positive
terminal of the battery and connect it.
➤ Lay the negative cable (black) (fig. 1 7, page 3) from the converter to negative
terminal of the battery and connect it.
7.2

Connecting the connection cable

You can switch on the device as follows:
• Using the main switch on the device (fig. 1 6, page 3)
• Using the ignition (fig. 5 A, page 4)
Terminal 15: Connected positive terminal
• Using an external switch (fig. 5 B, page 4)
Connecting the converter to be switched on via the main switch
➤ Isolate the connecting line so no malfunction can occur.
Connecting the converter to be switched on via the ignition
➤ Connect the connecting line to terminal 15 (connected positive terminal)
(fig. 5 A, page 4).
➤ Set the main switch (fig. 1 6, page 3) on the back of the converter to "0"
permanently.
14
PerfectCharge/PerfectPower
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Perfectcharge dc 20Perfectcharge dc 40Perfectcharge dc 40 estorePerfectpower dcdc 10Perfectpower dcdc 20Perfectpower dcdc 40

Table des Matières