Technical Data; Use For Intended Purpose; Electrical Connection; Extension Cable - Festool OF 1400 EQ Guide D'utilisation

Table des Matières

Publicité

6
1.1 Speed controller / Régulateur de vitesse de rotation /
Regulador del número de revoluciones
1.2 Locking button / Bouton de blocage / Botón de bloqueo
1.3 On/Off switch / Interrupteur marche/arrêt / Interruptor
de conexión/desconexión
1.4 Scale / Graduation / Escala
1.5 Spindle stop / Dispositif d'arrêt de l'axe / Dispositivo de
bloqueo del husillo
1.6 Pivoted turret stop / Butée tournante / Tope de revólver
1.7 Collet nut / L'écrou de la pince de serrage / Tuerca de la pinza
Various dust created by power sanding, sawing,
grinding, drilling and other construction activities contains
chemicals known (to the State of California) to cause cancer,
birth defects or other reproductive harm. Some examples
of these chemicals are:
• lead from lead-based paints,
• crystalline silica from bricks and cement and other masonry
products, and
• arsenic and chromium from chemically-treated lumber.
The risk from these exposures varies, depending on how
often you do this type of work.
To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment,
such as dust masks that are specially designed to filter out
microscopic particles.

Technical data

Power
Voltage
No load speed
Quick height adjustment
Fine height adjustment
Router diameter, max.
Drive shaft connection of the spindle
Weight
Safety
acc. to IEC 745, UL 745, CSA C22.2 No. 745
V
Volts
A
Amperes
Hz
Hertz
~
Alternating current
n
No load speed
0
Class II Construction
rpm
Revolutions or reciprocation per minute
Ø
Diameter

Use for intended purpose

The routers are designed for routing wood, plastics and similar
materials. Aluminium and plasterboard can also be processed
with corresponding cutters such as are listed in the Festool
catalogues.
The user is liable for damages and injuries due
to incorrect usage.

Electrical connection

The network voltage must conform to the voltage indicated
on the rating plate. A 16 A safety fuse (for 120 V) or a
corresponding protective circuit-breaker is required.
See Fig. 2 for connection and disconnection of the power cable.
Always switch the machine off before connecting
or disconnecting the power cable!

Extension cable

If an extension cable is required, it must have a sufficient
cross-section so as to prevent an excessive drop in voltage or
overheating. An excessive drop in voltage reduces the output
and can lead to failure of the motor. The table beside shows
you the correct cable diameter as a function of the cable length
for the router OF 1400 EQ. Use only U.L. and CSA listed
extension cables. Never use two extension cables together.
Instead, use one long one.
Note: The lower the AWG number, the stronger the cable.
~ 120 V, 60 Hz
10 000 - 22 500 rpm
70 mm (2.76")
8 mm (0.31")
4.5 kg (9.9 lbs)
Symbols
12 A
63 mm
M 22 x 1

Publicité

Table des Matières
loading

Table des Matières