Typical Installation - Samoa 530610 Guide D'instructions Et Pièces De Rechange

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
DESCRIPTION
Compressed air operated piston-type reciprocating pump. This high flow capacity pump is compatible with mineral and synthetic grease
and suitable for large installations with long lengths of piping supplying several outlets simultaneously. This pump is mounted directly on
20 kg, 50 kg and 185 kg drums.
WARNINGS
WARNING: Read all instruction manuals, tags, and labels
!
before operating the equipment. This equipment is for
professional use only.
• The use of non compatible fluids may cause damage in the pump
and serious personal injury. This equipment is not intended for use
with fluids that fall within the Group 1 fluid as defined that are
explosive, extremely flammable, highly flammable, flammable, very
toxic, toxic, oxidizing or where the vapor pressure if greater than 0,5
bar (7 psi) above the pressure atmospheric at the maximum
allowable temperature.
• The pump generates high or very high pressures. Do not exceed the
maximum air inlet pressure of 10 bar (145 psi).
• A direct hit against the human body may result in an injury.
INSTALLATION
It is recommended to install this pump on a drum using the bundled
bung adapter (609106) with a suitable drum cover (418006 for 185
kg drum, 418004 for 50 kg drum and 418002 for 20 kg drum).
Fasten the cover onto the drum and screw the nut of the bung
adaptor securely into the 2" bung opening of the cover. Insert the
pump through the nut and adjust it with the star nut to the desired
height (see figure 2).
It is also possible mounting the pump directly fastened on a flat
surface, using the 4 threaded holes (M8) disposed in a ∅90 mm
pattern in the fluid outlet body.

TYPICAL INSTALLATION

Figure 3 is a typical installation shown with all the recommended
accessories for the pump to operate correctly.
NOTE: The compressed air supply must be set between 2 and 10 bar (29
and 145 psi), being 6 bar (90 psi) the recommended pressure. An air
closing valve must be installed, in order to be able to close the
compressed air line at the end of the day (If the air inlet not is closed
and there is a leakage in some point of the grease outlet circuit, the
pump will start automatically, emptying the container).
Pos
Description
A
Air shut off valve
B
Filter regulator
C
Air hose
D
Quick coupling
E
Connection nipple
F
Pump (185 kg drum)
G
Grease hose
H
Grease shut off valve
I
Cover
J
Follower plate
K
Pressure Relief Valve
2
853 823 R. 02/17
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
Part No.
950319+239004
241001
247710
251438
255338
530610
945676+841700+945557
950304
418006
417012
• This unit may have stored pressure, release all pressure and disconnect
from any fluid systems before servicing. To ensure safe operation of this
unit, all service work should be by qualified personnel only.
• When not in use, be sure to shut off the air supply to avoid accidents.
• Do not alter or modify this equipment. Use only Samoa Industrial,
S.A. genuine components. Any unauthorized tampering with this
equipment, improper use, poor maintenance or removal of
identification labels may invalidate the guarantee.
• All fittings in the system connected to the outlet of the pump should
be suitable for the maximum possible pressure generated by the
pump/air motor. If the systems cannot be designed to take the
maximum pressure produced by the pump, safety valves or diverter
valves should be fitted.