BURNER ASSEMBLY GASKET
EXAMINATION PROCEDURE
NOTE: It is imperative that this procedure be completed at least twice yearly.
1. Turn unit to ON. The burner must be firing during this procedure.
2. Using a stainless steel extension mirror, inspect gasket between burner
pan assembly and skillet pan (sides and front only).
3. Replace gasket if:
- gasket shows signs of deterioration
- a flame can be seen coming through the gasket
- condensation forms on the extension mirror (indicating escaping heat)
GASKET PART #s
30 GALLON
SIDES
SK2472402
FRONT
SK2472400
40 GALLON
SK2472402
SK2472401
SKILLET PAN
GASKET