Supply includes (picture 1)
1.
Compressed air connector
2.
Control lever
3.
Handle
4.
Tool hold
Appliance
22000 PRO PNEUMATIC ROD GRINDING MACHINE
Professional pneumatic rod grinding machine with a double-
embedded shaft, rubbered handle for effortless work with
minimum vibrations. Due to the foul air channel, there is no
dust swirl on the work-piece! Safety switch against
unintentional switching on.
Technical data
Service pressure:
Air consumption:
Max. free-running revs:
Recomm. hose cross sect.:
Lwa noise data:
Air connection:
Vibration acceleration:
Weight:
General safety instructions
Please read carefully these Operating Instructions.
Familiarise with the control elements and appropriate
appliance using. Keep the Operating Instructions for future
reference.
Safe working
Keep the place of your work clean!
Mess in the place of your work may result in injuries.
Consider the environment influences
Do not expose the appliance to rain.
Do not use the appliance in a wet or moist environment.
Provide appropriate lighting.
Do not use the appliance near flammable liquids or gases.
Keep other persons in safe distance!
Do not let other persons, especially children, touch the
appliance and the cable. Keep them in a sufficient distance
from the place of your work.
Store the appliance properly!
An appliance that is not used should be stored in a dry,
locked place out of reach of children.
Do not overload the appliance!
Work in the specified output limits.
Use the right appliance!
Do not use the appliance for purposes for which it has not
been designed.
Look after your appliance!
Follow the maintenance regulations and instructions.
Check regularly the appliance cable and have it replaced by
an authorised professional if damaged.
Check regularly the extension cable and replace it if
damaged. Keep the handles dry, with no oil and grease.
Be careful!
Pay attention to what you are doing. Use common sense
when working. Do not use the appliance when you are tired.
6.3 bar
113 - 540 l/min
22000 U/min
10 mm
97 dB
¼ "
2,5 m/sec²
0,6 kg
8
WARNING!
Use of any other accessories may pose a risk of injury.
Your appliance should be repaired by an electrician only!
This appliance meets the appropriate safety provisions.
Repairs may only be executed by an electrician and original
spare parts must be used, otherwise the user may face a risk
of injury.
Appliance-specific safety instructions
Safety notice! Failing to follow these instructions
can cause an injury to you or other persons.
1.
Read the following Operating Instructions for using the
pneumatic appliance and follow the safety instructions
for using the pneumatic appliance.
2.
ALWAYS wear approved protective glasses, earphones,
a respirator and safety gloves!
3.
Disconnect the appliance from air supply if not used.
NEVER replace any parts of the accessories or
SERVICE them if the appliance is connected with the air
supply.
4.
Ensure that your hands could freely move while working
on the appliance to be able to execute the work safely.
5.
Use the appliance only at a speed for which it has been
designed.
6.
Properly maintain the appliance and follow all
instructions for appliance lubrication and maintenance.
7.
Do not damage the hoses and connecting pieces by
carrying the appliance with its hose or by disconnecting
the hose from the air supply by pulling. Prevent the hose
from coming into contact with high temperatures, oil and
sharp edges. The hose should be replaced if damaged
or worn out.
8.
Use the appliance with allowable service pressure only.
Higher pressure would shorten the service life of your
appliance as a result of higher load.
9.
There can be sparks during the grinding process.
10. Do not use any damaged grinding material.
11. Do not needlessly use long pneumatic hoses to avoid
tripping.
12. Never leave the pneumatic appliance unattended.
13. Never put the appliance near people or animals.
14. Never aim at people or animals with the air current.
15. Never put the pneumatic appliance near body holes – it
can lead to injuries dangerous to life!
16.
Injury by stone.
17.
Attention! Parts breaking off!
Beware of the rotary tool!
Operation
Wear protective glasses! Wear earphones! Wear
safety gloves!
Before everyday use, please empty the water from the
compressor tank and blow the condensation from the air
hose.
If seal has not yet been applied on the pneumatic insertion
wrap it with a Teflon tape (picture2 and 3)
•
Start the compressor.
•
Fix the required grinding shank to the pneumatic
grinder.
•
Connect the pneumatic grinder with the pneumatic
hose. Caution! Do not exceed the maximum operating
pressure!
•
Start working by pressing the Start button.