ENGLISH
To go back to the functions without any change press the MENU button again for about 2seconds.
Display Inversion
Display normal: display is readable when the unit is on the floor.
Display inversion: display is readable when the unit is mounted upside down.
 Press the MENU button until the display shows
 Press the ENTER button, the display starts blinking.
 Use DOWN and UP buttons to select
(display inversion) or
 Once the mode is selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again for about 2seconds.
Color Mode
Used to put a certain color on all 4 LED panels.
 Press the MENU button until the display shows
 Press the ENTER button, the display starts blinking.
 Use the DOWN and UP buttons to select one of the 9 pre-programmed colors (
press ENTER to confirm.
 You can also choose the manual color mode (display =
color. Once you press ENTER the following screens appear:
Brightness of RED color can be changed from 0% to 100% (r..0 to r255)
Brightness of GREEN color can be changed from 0% to 100% (G..0 to G255)
Brightness of BLUE color can be changed from 0% to 100% (b..0 to B255)
 Press the MENU button for about 2 seconds to save the settings and return to normal working mode. (or
automatically return to the main functions without any change after 8 seconds)
Self-Test
Run a built-in self-test program
 Press the MENU button until the display shows
 Press the ENTER button, the display starts blinking: the unit runs abuilt-in self-test program.
To go back to the functions without any change press the MENU button again for about 2seconds.
Fixture Hours
Used to show the number of working hours of the unit.
 Press the MENU button until
is blinking on the display.
 Press the ENTER button to show the number of working hours in the display.
To go back to the functions without any change press the MENU button again for about 2seconds.
Software version:
Used to show the software version of the unit.
 Press the MENU button until
blinks on the display.
 Press the ENTER button to show the software version of the unit.
To go back to the functions without any change press the MENU button again for about 2seconds.
ELECTRICAL INSTALLATION + ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Electrical installation for 1 standalone unit:
 Just insert the mains cable. The unit starts working immediately in stand-alone mode.
Remark1: You can connect a CA-8 remote controller to the unit if you want to have more control. Refer to
"how to operate the unit" to learn how to do this.
Remark2: if there's no output, please make sure to set the unit in master mode and set the blackout mode
to "NO" (see previous chapter)
JB SYSTEMS
®
OPERATION MANUAL
(normal display).
.
to
) if you want to compose your own custom
7/77
LED DJ-BAR
ENGLISH
Electrical installation for two or more units in master/slave:
 Connect 2 to maximum 16 units together using good quality balanced microphone cables. The first unit
in the chain will automatically act as master, the other units will act automatically as slaves.
 Make sure that all units are connected to the mains.
 Done!
Remark: You can connect a CA-8 remote controller to the master unit if you want to have more control
over the master/slave operation
Electrical installation in Master/slave-mode with the LEDCON-02 remote:
) and
 Up to 42 LED DJ-BAR units can be daisy chained and connected to the output of en optional LEDCON-
02 remote using a good quality balanced cable.
 All connected units are automatically switched as slaves.
IMPORTANT REMARK: to make sure everything works well you MUST set the LED DJ-BAR in
"LEdC" channel mode and perform the "automatic address distribution" feature on the LEDCON-02
before using the set for the first time!!! (check the user manual of your LEDCON-02 to see how this
is done)
Electrical installation in DMX-mode:
 The DMX-protocol is a widely used high speed signal to control intelligent light equipment. You need to
"daisy chain" your DMX controller and all the connected units with a good quality balanced cable.
 Both XLR-3pin and XLR-5pin connectors are used, however XLR-3pin is more popular because these
cables are compatible with balanced audio cables.
Pin layout XLR-3pin:
Pin layout XLR-5pin:
(+) ~ Pins4+5 not used.
 To prevent strange behavior of the light effects, due to interferences, you must use
a 90Ω to 120Ω terminator at the end of the chain. Never use Y-splitter cables, this
simply won't work!
 Make sure that all units are connected to the mains.
 Each light effect in the chain needs to have its proper starting address so it knows which commands
from the controller it has to decode. In the next section you will learn how to set the DMX addresses.
 HOW TO SET THE RIGHT STARTING ADDRESS:
Refer to the previous chapter (DMX-512 address setting) to learn how to set the starting address on this unit.
The starting address of each unit is very important. Unfortunately it is impossible to tell you in this user
manual which starting addresses you have to set because this completely depends on the controller you will
use... So please refer to the user manual of your DMX-controller to find out which starting addresses you
must set.
JB SYSTEMS
Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+)
Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal