Installation
5.2
Installation location
Ensure the following conditions are fulfilled for the
installation location:
•
Frost safe room.
–
In damp rooms, use a platform.
•
Load bearing, level floor.
•
Collection tray with connected drain.
•
Allow for the minimum distances to the side and
above.
•
Take the position of the connections from the
technical data.
see chapter 4 "Technical data" on page 6
5.3
Tank assembly
Make the connection to the cylinder at the cold water pipe in accordance with DIN 1988.
1
Hot water (WW)
2
Circulation (ZK)
3
Heat flow (HV)
4
Boiler (HK)
5
Heat return (HR)
6
Cold water (KW)
Note!
Prevent natural circulation of the water.
–
Use non-return valves or check valves with backflow preventers in the cylinder circuits.
10 — English
7
8
9
10
11
Storatherm — 25.07.2018
Isolation valve
Return flow prohibiter (pipe separator)
Diaphragm expansion vessel
Drain
Electrical backup