Sanitation
Sanitation of Manikin Faces, see separate sheet.
Little Anne Airway
The Little Anne Airway is designed for disposal after each class.
Fig. 3
1a
4a
To remove Fig. 3
1a Detach manikin face at each ear.
2a Lift manikin face off valve coupling.
3a Remove jaw from posts in head.
4a Remove valve.
5a Open chest cover.
6a Remove used airway and discard.
Fig. 4
1b
4b
2a
5a
To install Fig. 4
1b Lay lung flat on torso and attach to hook.
2b Snap airway valve onto jaw.
3b Reattach jaw to posts in head.
4b Fasten chest cover onto the four retainers.
5b Push face coupling into airway valve.
6b Fasten face onto retainers at each ear.
2b
5b
4
3a
6a
3b
6b