Troubleshooting - Dometic CFX Série Notice D'utilisation

Masquer les pouces Voir aussi pour CFX Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
CFX100W
10

Troubleshooting

Fault
Device does not
function, LED does
not glow.
The device does not
cool (power is
connected, "POWER"
LED is lit).
The device does not
cool (power is
connected, "POWER"
LED flashes orange,
display is switched
off).
The display shows an
error message (e.g.
"Err1") and the
appliance does not
cool.
The interior light of a
compartment flashes.
EN
Possible cause
Battery voltage is too
low.
The DC fuse is
defective.
No voltage present in
the AC voltage outlet.
The AC fuse is
defective.
The integrated mains
adapter is defective.
Defective compressor.
Battery monitor is set
too high.
Battery voltage is too
low.
The appliance has
switched off due to an
internal fault.
The lid of the
compartment has been
left open for more than
three minutes.
Suggested remedy
Test the battery and charge it as needed.
Replace the DC fuse, see chapter
"Replacing the DC connection cable
fuse" on page 27.
Try using another plug outlet.
Replace the AC fuse, see chapter
"Replacing the AC fuse" on page 27.
This can only be repaired by an
authorised repair centre.
This can only be repaired by an
authorised repair centre.
Select a lower battery monitor setting.
Test the battery and charge it as needed.
This can only be repaired by an
authorised repair centre.
Close the lid of the compartment.
Troubleshooting