12. Troubleshooting

Error / error detection
Possible causes
• No flow through the device
• Device connected
incorrectly, inflow/outflow
switched
• Container fills to
• Leakage between bottle
overflowing
and head, defective float
switch
• Pressure is reduced too
• Junction closed too far,
much throughout the device
device too small
• Drain hose keeps running
• Back pressure too high in
continuously
the drain hose
• Device does not regenerate,
• No signal from the flow
"Holiday Mode" LED is lit
meter
permanently (>10 minutes)
even though water was
tapped
•No or inadequate operation
• Device set to "Bypass
Mode"
•No or inadequate operation
• Junction opened too far
•No or inadequate operation
• No material available for
use in the reservoir. Wrong
material for use.
•Device smells of chloride
• Normal to a certain extent
when running in the
regeneration mode, since
the drain hose has been
opened. If the smell is very
strong gas might be
leaking from the chloride
generator unit.
• Uses too much
• Junction closed too far
magnesium
(cleaning mode). Water
hardness has been set too
high.
• Does not use enough or no
• Junction opened too far.
magnesium
Device in holiday mode.
Brine line is clogged.
28
GB
Remedial measures
• Correctly connect the
device.
• Retighten connection.
Check float switch.
• Open junction all the way to
the coloured tag. Install a
model that accommodates a
higher flow rate.
• Clean drain hose, shorten if
necessary
• Check the wiring of the flow
meter, replace the flow
meter (Customer Service)
•Move the red bypass lever
to the service position
•Close the junction by
turning counterclockwise
•Refill reservoir with: VC 51-A
in the magnesium mode
add block salt during the
softening treatment mode
• Retighten the connection at
the chloride generator unit,
replace the lock rings if
necessary.
• Turn back to Wellness
Mode. Check the water
hardness setting.
• Check the position of the
junction. Check the flow
meter. Check the brine line.
Error / error detection
Possible causes
• Magnesium turns to lumps
• Might be due to fluctuations
in the cabinet
in temperature and occur in
the cabinet.
• Brown deposits have
• The material for use is
settled in the reservoir
added normally
• The pressure is reducing
• Increasing iron deposits in
slowly throughout the
the gum
device
• Time display is flashing
• Device has been subjected
to a power failure
• Wrong display in Display/
• Operating program has
Indicator „H——25"
been deleted
• Efficacy has been
• Increasing iron deposits in
decreasing slowly
the gum
GB
Remedial measures
• Pour a cup of hot water over
the lump. Stir until the lump
is dissolved.
• Remove during annual
maintenance.
• Replace gum (Maintenance
Kit R)
• Reset the clock (does not
effect functioning).
• Call Honeywell Customer
Service
• Replace gum (Maintenance
Kit R)
29