Safety Instructions
The pump should not be exposed to the weather.
(UV-radiation, freezing, etc.)
Clean after each operation.
Ensure a proper ventilation of area where
pump and container are located.
Keep containers closed when not in use.
Control the operating pressure by a pressure controller
and the pumping cycle by a speed regulating valve.
Do not exceed the maximum operating air pressure
P
Nmax.
(P
Nmax.
Excessive air pressure can cause personal injury,
pump or property damage.
The built-in 5/2-way air valve is a precision part which
may be operated with oil-free, clean and dry compressed
air only. In case of humid compressed air, a water separator
must be used. We recommend to use a 5 μm air filter to
guarantee a troublefree function of the 5/2-way air valve.
Always use a silencer or an exhaust air hose.
Recommended minimum inside diameter of air hose :
RFM / RFML 10
RFM / RFML 15
RFM / RFML 25
RFM 40
10
stated on the name plate.
at 20 °C operating temperature)
Model
Air supply hose
.
Air exhaust hose
DN 10
DN 10
DN 10
DN 13
DN 10
DN 10
DN 10
DN 13