geo-FENNEL FL 70 Premium-Liner SP Mode D'emploi page 26

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
IMPORTANT – to detect the laser beam move the receiver FR 55 up and down slowly. The
FL 70 Premium-Liner SP and the FR 55 are not working with the same technology as rotating laser
levels. Because of this the receiver FR 55 must be moved much more sensitively.
USE OF THE RECEIVER
Press button (3) to power on the receiver (red light). Activate the pulse
function (P) at the line laser.
Move the receiver FR 55 up and down slowly to detect the laser
beam.
Detection of the laser signal and corresponding LED
indication (front, rear, sideways):
A Move the receiver down
Acoustic signal: ultra-short frequent beep
B Move the receiver up
Acoustic signal: short frequent beep
C On level
Acoustic signal: continuous beep
CLAMP FOR LEVELLING STAFF
If required mount the FR 55 to its clamp. It can then be attached to laser poles or any other equipment.