The assignment of a temperature button with a low "set-
back" temperature, gives you the option of manual tempera-
ture decrease when the soldering iron is not being used.

5. Special functions

The special function are splitted in two menu sections.
Special functions menu 1: often used functions like
STANDBY, OFFSET, SETBACK, ...
Special functions menu 2: Calibration function, Remote Id
2 sec.
2
(EXIT)
5.1 Special functions menu 1
Select the desired channel (CH1 or CH2) for inputting the spe-
cial functions. If the UP and DOWN buttons are pressed
simultaneously, after approx. 2 seconds the menu selection
for the special functions is activated and - I - appears in the
display, release buttons.
Menu selection
The following settings are possible:
Offset, setback, standby temperature, Auto off time, lock
function, window, temperature version.
Buttons
1
and I-II-III are used for menu selection.
Button
4 sec.
-1-
-2-
Resetting the special functions to factory settings.
Press and hold the
DOWN buttons at the same time. "FSE" appears in the dis-
play. The soldering station is now reset to its factory calibra-
tion.
5.1.1 Standby temperature
When the set setback time has elapsed, the specified tempe-
rature is decreased automatically to the standby value. The
actual temperature is displayed (flashing) and "STANDBY"
appears in the display.
Adjust the standby temperature with the UP or DOWN button.
Switch to the previous menu item with
Switch to the next menu item with I-II-III.
Exit
2
is used to exit the menu again (EXIT).
1
I-II-III
STANDBY
OFF
OFFSET
SETBACK
WINDOW
°C / °F
2
button. Then press the UP and
English
2
EXIT