TABLE "B" LOGIC MENU
LOGIC
DEFAULT
ON
TCA
OFF
antipanic
OFF
ASTER
OFF
revolving
OFF
iNT EXT
TEST PHOT
OFF
open
TEST PHOT
OFF
close
ra blow c. o p
OFF
OFF
fixed code
OFF
radio prog
OFF
Inv. dir.
Presence
OFF
sensors
Definition of individual radar modes
• Radar A external door (1)
With doors closed, it activates opening of the external door and allows entry
inside the cage door. If the internal door is open, this door is closed before
the external door is opened. In the event of simultaneous operations, the
external door is given priority. Once the external door is closed, it activates
opening of the internal door and allows entry inside the building.
• Radar B
positioned in the middle of the cage door
presence of a person inside the cage door and, during exit, allows the external
door to open once the internal door has closed. In an emergency, once the
person has entered the cage door, if the other door fails to open, it allows the
door they have just entered through to be opened again.
• Radar C internal door (2)
With doors closed, it activates opening of the internal door and allows entry
inside the cage door from inside the building. If the external door is open,
this door is closed before the internal door is opened. In the event of simul-
taneous operations, the external door is given priority.
15.12) DIRECTION REVERSAL FIG. AK
INSTALLATION MANUAL
Cross out
using
setting
ON
Automatic Closing ON/OFF (TCA and Clear Time)
OFF
ON
Panic Feature ON/OFF (Section ANTI-PANIC FUNCTION)
OFF
ON
Master/Slave door (Sect. CONNECTING A NUMBER OF DOORS WITH CENTRAL CONTROL PANELS)
"ON" Door set as MASTER in connection for management of commands via central controllers.
"OFF" Door set as SLAVE in connection for management of commands via central controllers.
OFF
ON
"ON" Revolving mode. Single/revolving door (Sect. CONNECTING 2 DOORS IN cage MODE)
"OFF" Single door mode
OFF
ON
Internal/External door (Sect. CONNECTING 2 DOORS IN cage MODE)
"ON" Door set as EXTERNAL in "Revolving" mode.
"OFF" Door set as INTERNAL in "Revolving" mode.
OFF
ON
Safety device testing during opening
"ON" Device testing ON during opening
"OFF" Device testing OFF during opening
OFF
ON
Safety device testing during closing
"ON" Device testing ON during closing
"OFF" Device testing OFF during closing
OFF
ON
Hammer ON/OFF during opening
OFF
ON
ON:
Receiver is configured for operation in fixed-code mode.
OFF: Receiver is configured for operation in rolling-code mode.
OFF
ON:
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has already been
ON
memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters.
This mode does not require access to the control panel.
OFF
OFF: Disables wireless memorizing of transmitters. Transmitters are memorized only using the relevant Radio
menu.
ON
Change this parameter if the opening direction needs to be changed. Fig. AK
OFF
Standard operating mode. Fig. AK
The opening photocell input acts as a presence sensor: if it is active during opening, movement takes place at slow
ON
speed; during other manoeuvres, it has no effect.
The opening photocell input has standard function: during opening it blocks movement until it is released; when
OFF
the door is open, it resets the TCA or clear time, if occupied it will not allow opening or closing to start.