Measuring range
400 mV
4 V
40 V
400 V
1000 V
7.2 AC voltage ranges
The input resistance is 10 MΩ parallel 100 pF. The measurement value is
obtained as a true RMS value and displayed as such. With non-sinusoidal
curves, the value displayed is less accurate. This results in an additional error
for the following crest factors:
Crest factor of 1.4 to 3.0, additional error + 1.5 %.
Crest factor of 3.0 to 4.0, additional error + 3.0 %.
Measuring range
400 mV
4 V
40 V
400 V
750 V
± (1.5 % + 5 Digit) in frequency range 500 Hz - 1 kHz
*1
± (1.5 % + 5 Digit) for measuring ranges > 50 % of the measuring range value
*2
7.3 DC ranges
Overload protection
-
1 A (500 V) fuse, rapid on mA input
-
10 A (500 V) fuse, rapid on 10 A input
Measuring range
40 mA
400 mA
10 A
7.4 AC ranges
The measurement reading is obtained as a true RMS reading and displayed
as such. With non-sinusoidal curves, the value displayed is less accurate. This
results in an additional error for the following crest factors:
Crest factor of 1.4 to 3.0, additional error + 1.5 %.
Crest factor of 3.0 to 4.0, additional error + 3.0 %.
Overload protection:
-
1 A (500 V) fuse, rapid on mA input
-
10 A (500 V) fuse, rapid on 10 A input
Measuring range
40 mA
400 mA
10 A
7.5 Resistance ranges
Overload protection for resistance measurements: 600 V
Measuring
Resolution
range
400 Ω
0,1 Ω
10/ 2004
Resolution
100 µV
± (0.25 % of reading + 5 digits)
1 mV
± (0.4 % of reading + 1 digits)
10 mV
± (0.25 % of reading + 1 digits)
100 mV
± (0.25 % of reading + 1 digits)
1 V
± (0.25 % of reading + 1 digits)
Measurement accuracy in frequency range
Resolution
± (2.0 % of reading + 8 digits) in frequency
100 µV
range 50 Hz - 60 Hz for 400 mV-range
1 mV
± (1.3 % of reading + 5 digits)
10 mV
± (1.3 % of reading + 5 digits)
100 mV
± (1.3 % of reading + 5 digits)
1 V
± (1.3 % of reading + 5 digits)
Resolution
10 µA
± (0.6 % of reading + 2 digits)
100 µA
± (0.7 % of reading + 2 digits)
10 mA
± (1.0 % of reading + 3 digits)
Measurement accuracy in frequency range
Resolution
10 µA
± (2.0 % of reading + 5 digits)
100 µA
± (2.0 % of reading + 5 digits)
10 mA
± (2.5 % of reading + 5 digits)
Measurement accuracy
± (0.7 % of reading + 3 digits)
BENNING MM 6
Measurement accuracy
40 Hz - 1000 Hz
Measurement accuracy
40 Hz - 1000 Hz
Overload protection
1000 V
1000 V
1000 V
1000 V
1000 V
Overload protection
750 V
750 V
*1*2
750 V
*2
750 V
*2
750 V
*2
Voltage drop
200 mV max.
2 V max.
2 V max.
Voltage drop
200 mV
2 V
eff
2 V
eff
eff
Max. meas.
Max. no-load
current
voltage
700 µA
DC
DC
DC
DC
DC
eff
eff
eff
eff
eff
max.
eff
max.
max.
1,3 V