ADDRESS SETUP: Use control menu to set DMX address. The machine occupies 2
control channels. The starting address is defined as the first channel from which the
machine will respond the controller. Always double check to make sure there are no
overlapping channels in order to control the machine correctly.
CHANNEL 1
FAZE OUTPUT LEVEL
CHANNEL 1
FAN OUTPUT LEVEL
LIQUID
Only use Antari FLG water-based liquid for the F-5 Fazer. The machine is tested and
calibrated with this liquid to get the best output performance. Warranty will be void if
any other type of liquid is used, improper use of liquid may lead to machine failure
and malfunction.
SERVICE AND MAINTEANCE
-
Do not allow the machine to become contaminated
-
Remove dust from air vents with air compressor, vacuum or a soft
brush
-
Only use a damp cloth to clean the casing
-
Before storing run distilled water through the system to help avoid
condensing the pump or heater.
-
It is recommended to run the machine on a monthly basis in order to
achieve best performance and output condition
-
Excessive dust, liquid and dirt built up will degrade performance and
cause overheating.
DMX VALUE
0-4
5 - 255
DMX VALUE
0-4
5 - 255
FUNCTION
Faze off
Faze output 1-100%
FUNCTION
Fan20%
Fan 21 - 100%
13