5.3.3 Shielded high voltage cable Air gun ES-2J

With the shielded high voltage cable of the Air gun ES-2J, the earth connection must be
connected to the power unit through the union nut. The earth connection must be connected to
the power unit's internal earthing point.
See also figure 8b.
Terminal block
Union nut
Union nut
White hose
Figure 8a: Braided shielding finishing

5.4 Connecting the MPM power cable

(100 - 240 V AC) L
(100 - 240 V AC) N
Figure 9: MPM power cable
- Connect the power cable to the mains power point or fit a plug. See figure 9.
- Make the two earth connections, via the power cable and via the external earth wire, with the
earthing point on the MPM. Connect the external earth wire to an earthed machine part
MPM_UM_9752080610_NL_D_GB_F_V3_2
Internal earthing point
Power unit
External earthing point
Power unit
Earth connection
Braided shielding
Brown
Blue
Green/Yellow
Earth connection
Shielded
HV-cable ES-2J
Figure 8b: shielded HV cable ES-2J