Connection cables
for ionisation
equipment
Power cable
External
earth wire
(cable lug
ø6 mm)
I/O connector
(MPM-xxR)
Figure 3: Installing the MPM (shown without the cover)

5.2.2 Fitting the MPM

- Attach the MPM to a stable wall or machine part using the 6-mm diameter fixing holes in the
base plate.

5.3 Connecting the ionisation equipment

- Loosen the two screws on the top of the cover.
- Carefully remove the cover from the MPM. Ensure that the flat cable between the cover and
the PCB of the MPM is not damaged.
- Remove the seals (stoppers) from the point where the cable for the ionisation equipment has
to pass through.
- Screw the gland housing of the equipment being connected into the box.
- When using a coax cable, check whether the cable length from the PVC socket is 38 mm;
see Figure 6. If not correct, adjust. See also the manual for ionisation equipment.
- Plug the connection cable into the power unit via the gland housing.
- Screw the union nut onto the gland housing.
- Screw the unions of the equipment being connected into the box.
- Connect the high voltage cables for the ionisation equipment to the terminal block of the
transformer. Use a screwdriver for this.
Note:
Do not allow the high voltage cables to make a loop in the MPM;
instead they must pass directly from the unions into the connections opposite.
MPM_UM_9752080610_NL_D_GB_F_V3_2
High voltage cables
Terminal block for the
high voltage cables
Dipswitches
On/off
switch
Flat cable connector
46