Only for the MPM with remote control option (MPM-xxR): see chapter 6
if the remote high voltage on/off option is required The Ion balance
or the Biphase option must be switched on.
- Place the cover on the box.
- Secure the cover with the two screws.
Power unit
Gland housing
Union nut
Figure 4: Connecting the coax cable to the power unit

5.3.1 Shortening high-voltage cables

Warning:
- The electrical installation must be carried out by a skilled electrical engineer with the
relevant training and qualifications.
- Disconnect the power supply before carrying out work on the unit.
Ionisation equipment high voltage cables may be shortened.
However, the metal shielding must not be shortened by the customer.
Shielded coax cable must be finished as shown in Figure 6.
In the case of blue high-voltage cables, the end of the cable must be finished as shown in
Figure 7.
Note:
 Do not damage the layers of insulation underneath!
 When you are stripping high-voltage cables, do not bend them by a radius sharper
than 45 mm. Sharper bends will shorten the service life of the cable!
MPM_UM_9752080610_NL_D_GB_F_V3_2
Coax cable
Union nut
GB
47