Parametro - Parameters -
Paramètre - Parameter - Parámetro
ADDR217
INTERNAL ADDITIONAL ELECTRIC
HEATERS
ADDR220
REMOTE CONTROLS
ADDR221
PERIODIC PUMP ACTIVATION
ADDR222
PUMP ACTIVATION DELAY
ADDR223
PUMP ACTIVATION LENGTH
ADDR224
PUMP MAINTENANCE WARNING
INTERVAL
ADDR225
WATER FILTER MAINTENANCE
WARNING INTERVAL
ADDR226
EXTERNAL BOILER REQUEST
ADDR227
T4 OUTDOOR TEMP. THRESHOLD
FOR EXTERNAL BOILER REQUEST
ADDR228
DOMESTIC HOT WATER
ADDR229
LEGIONARY DISEASE MODE
SELECTION
ADDR230
LEGIONARY DISEASE SAFETY
FUNCTION INTERVAL
ADDR231
LEGIONARY DISEASE SAFETY
FUNCTION START TIME
ADDR232
LEGIONARY DISEASE SAFETY
FUNCTION TEMPERATURE
ADDR233
LEGIONARY DISEASE SAFETY
FUNCTION DURATION
Range
Default
Range
Default
Plage
Default
Wertebereich
Default
Range
Default
0,1,2,3,4
0
0,1,2
0
1=ON,0=OFF
1=ON
0 -100
72
hour
0 – 600
30
second
0-1000 day
0
0-1000 day
0
1=ON, 0=OFF
0
-15 to 20°C
2
0,1,2
2
0,1,2
0
0 – 30
day
0
00.00 – 23.59
02.00
50°C – 80°C
65°C
0 – 240
30
minute
Commenti - Comments -
Commentaires - Anmerkungen -
Comentarios
0 = no stages enabled
1 = 1 stage enabled
2 = 2 stages enabled
3 = 1 stage enabled for low temperature
start
4 = 2 stages enabled for low temperature
start
0 = none (on board display only)
1 = remote communication port only
2 = remote switches only
NOTE: ECO, Night, DHW and TA contacts
inputs are always enabled
0 = disabled
0 = disabled
output 14 15
226(ON)= Boiler
226(OFF)=Auxiliary electric heater
0 = disabled
1 = set by DHW input
2 = set by DHW sensor T3
0 = heat pump+ electric heater (output K5
K5)
1 = electric heater only (output K5 K5)
2 = EH1 EH2 electric heaters
0 = disabled
X - 1
TOWER BIG