Anleitung WW 1200 - WW 2000_SPK1:Anl WH 2000 PTC SPK1
GB
2. Layout
WW 1200 (Fig. 1)
1 Foot
2 Heat setting switch
3 Thermostat control
4 LED temperature indicator
5 LED heat setting 500 W
6 LED heat setting 700 W
WW 2000 (Fig. 2)
1 Foot
2 Heat setting switch
3 Thermostat control
4 LED temperature indicator
5 LED heat setting 1000 W
6 LED heat setting 2000 W
3. Proper use
The equipment is designed for heating enclosed, dry
rooms. It primarily emits heat by radiation straight on
to objects and people who are in front.
The equipment can be used indoors in a free
standing position or mounted on a wall. Maintain all
minimum distances. The equipment may only be
used completely assembled and standing vertically.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the manufacturer
will be liable for any damage or injuries of any kind
caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data:
WW 1200
Rated voltage:
Output:
1200 W (500 W/ 700 W/ 1200 W)
Thermostat control:
Protection class:
Protection type:
Mains lead:
10
WW 2000
Rated voltage:
Output:
Thermostat control:
Protection class:
Protection type:
Mains lead:
5. Assembly
5.1 Free-standing installation
Observe Section 1 "Safety Instructions ".
Important! To prevent damage when attaching the
feet to the radiator, place the radiator upside down on
a soft surface (e.g. a carpet).
Slide the feet into the guides (Fig. 3) and fasten them
at the point marked (Fig. 4) with the screw provided.
5.2 Wall-mounting
Observe Section 1 "Safety Instructions ".
Do not attach the feet if the appliance is to be
mounted on the wall.
When selecting the location for the appliance,
please note that if there are skirtings on the floor
the minimum distance to the housing, or the
installation height, has to be measured from the
top of the skirting.
If the wall bracket is mounted on the back of the
radiator housing, pull it down and off (Fig. 5)
Then drill the two fastening holes with 6 mm
diameters, making sure they are horizontal, and
screw the wall bracket to the wall (Fig. 6).
Fit the radiator to the wall bracket and press it
down until the wall bracket audibly locks into
place. The radiator should now be mounted on the
wall as shown in the illustration (Fig. 7).
6. Starting up
230 V ~ 50 Hz
Important! Before using the appliance for the first
time, check that the voltage supply is the same as
Infinitely adjustable
the voltage details set out on the rating plate.
Read the safety instructions listed in section 1.
I
When the heater is used for the first time or after a
IP24
long period of rest it may emit an odor for a short
3 x 1 mm
2
x 1.8 m
26.08.2009
13:35 Uhr
Seite 10
230 V ~ 50 Hz
2000 W (1000 W / 2000 W)
Infinitely adjustable
3 x 1 mm
2
x 1.8 m
I
IP24