Parts Supplied—
15,000-24,000 BTU Models
Check that all parts are included in parts package.
NOTE: Not all parts are included with all models.
A
B
C
D
H
G
F
L
M
N
A. Foam seal with
adhesive strip
B. Foam seal without
adhesive strip
C. Side curtain bracket x2
D. Safety lock
E. Sill angle bracket x2
F. 1/2" hex-head screw x2
G. 5/8" hex-head screw x4
H. 5/16" hex-head screw x10
I. 5/8" flathead bolt with
locknut x2
E
J
K
I
Left
Right
O
J. 1/2" flathead bolt with
locknut x4
K. Gasket x2
L. Top channel (appearance
may vary)
M. Window support
bracket x2
N. Side curtains x2
O. Side retainers x2
Other: AAA batteries x2
Location Requirements—
Window Installation
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed.
Make sure you have everything necessary for correct installation.
The location should provide:
Grounded electrical outlet within 6 ft (183 cm) of where
■
the power cord exits the air conditioner. Do not use an
extension cord.
Free movement of air in room to be cooled.
■
A large enough opening for the air conditioner. Installation
■
parts are supplied for double-hung windows.
NOTE: The air conditioner can be installed without the side
panels to fit in a narrow window opening.
Adequate wall support for weight of air conditioner.
■
Firm wood, masonry, or metal to secure to supporting parts.
■
NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.
Window Opening Measurements
Model BTUs
Width (A)
6,000-8,000
23"−36"
(58.4 cm−91.4 cm)
10,000-12,000
26"−36"
(66 cm−91.4 cm)
15,000-18,000
28"−41"
(71.1 cm−104.2 cm)
22,000-24,000
30"−41"
(76.2 cm−104.2 cm)
A
B
Minimum
Opening (B)
14
⁄
"
1
2
(36.8 cm)
16"
(40.6 cm)
19"
(48.3 cm)
19
⁄
"
1
2
(49.5 cm)
5