Water values in ppm, µS/cm
In order to ensure a good water quality of the
reverse osmosis unit, the "Out" value indicated by
the RO monitor should read between 2 to 20 ppm
(approx. 5 – 50µS/cm). The "In" value indicated
varies depending on the tap water, e.g. 504 ppm.
The difference between the water values at the inlet
and at the outlet renders a picture of the purifying
capacity of the unit. At a water value of the outlet
water of over 20 ppm, the thin-film composite
membrane should be replaced.
Conversion into µS/m: Approximate value only: At
25° Celsius (77° F) 1 µS/cm corresponds to 0.5 ppm
or 1 ppm = 2 µS/cm.
Valeurs de mesure en ppm, µS/cm
Pour garantir une bonne qualité d'eau en sortie
de l'osmoseur inverse, la valeur "OUT" sur le RO
Monitor doit se situer dans une fourchette comprise
entre 2 et 20 ppm (env. 5 – 50µS/cm), par exemple
4 ppm. La valeur "IN" en entrée varie en fonction de
la qualité d'eau, par exemple 504 ppm.
La différence entre les valeurs en entrée et en sortie
d'osmoseur donne une image de la capacité de
retenue de l'osmoseur inverse. Pour une valeur en
sortie d'osmoseur de plus de 20 ppm, la membrane
TFC doit être remplacée.
Conversion en µS/cm : donnée seulement à titre
indicatif car très dépendante des liaisons entre
les différents sels dissous : 1µS/cm avec 25°C
correspond env. à 0,5 ppm, 1 ppm correspond à 2
µS/cm.