ENGLISH
Table of contents
5.0 Use .................................................................. 18
7.0 Service ............................................................ 20
10.0 Recycling ....................................................... 21
Figures ................................................................. 64
Register your fi replace at jotul.com for a
25-year warranty.
Product:
On all our products there is a label
Jøtul
Room heater fired by solid fuel
indicating the serial number and year.
Standard
:
Write this number in the place indicated
Minimum distance to adjacent combustible materials:
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
:
in the installation instructions.
Flue gas temperature
:
Nominal heat output
:
Efficiency
:
Operation range
:
Fuel type
:
Operational type
:
Always quote this serial number when
The appliance can be used in a shared flue.
contacting your retailer or Jøtul.
Country
Classification
Certificate/
Approved by
standard
Norway
Klasse II
SP Sveriges Provnings- och
Sweden
SP
OGC
Forskningsinstitut AB
SP Swedish National
Testing and Research
EUR
Intermittent
EN
Institute
Follow user`s instructions. Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlenen Brennstoffen.
Respectez les consignes d'utilisation. Utilisez uniquement
les combustibles recommandés.
Serial no: Y-xxxx, Year: 200x
Serial no.
Manufacturer:
221546
Jøtul AS
POB 1441
N-1602 Fredrikstad
Norway
16
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including those that refer to national and
European standards, shall be complied with when installing the
product.
Instructions for mounting, installation and use are enclosed with
the product. Prior to using the product the installation must be
inspected by a qualified person.
A product data label in heat resistant material can be found on the
heat shield underneath the product. This contains information
about identification and documentation for the product.
2.0 Technical data
Material:
Finish:
Fuel:
Log length, max:
Flue outlet:
Flue pipe dimension:
Approx. weight:
Optional extras:
Dimensions, distances:
Technical data according to EN 13240
Nominal heat output:
Flue gas mass flow:
Recommended chimney draught:
Efficiency:
CO emission (13% O
):
2
Flue gas temperature:
Operational type:
Cast iron
Black paint
Wood
40 cm
Top, rear
2
Ø 175 mm, 240 cm
cross section
106 kg
Decorative enamelled floor
plate in blue black - Rear heat
shield, short legs* (see 8.0)
See fig. 1
6,5 kW
4,8 g/sec
12 Pa
79%@7,4kW
0,30%
330
o
C
Intermittent