Intended Use; Assembly And Adjustments - DeWalt DCF6201 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INTENDED USE

This collated drywall magazine attachment is designed to be used
with the DCF620 or DCF621 D
professional driving of collated screws.
DO NOT use under wet conditions or in presence of flammable
liquids or gases.
This collated drywall magazine attachment is a professional power
tool. DO NOT let children come into contact with the tool. Supervision
is required when inexperienced operators use this tool.

ASSEMBLY AND ADJUSTMENTS

WARNING: To reduce the risk of injury, turn unit off and
disconnect it from power source before installing and
removing accessories, before adjusting or when making
repairs. An accidental start-up can cause injury.
Fitting the Collated Screwdriver Bit
(Fig. 1, 2)
NOTICE: For proper operation only use D
bit (catalog #: DWA6PHC2).
1. Remove the nose cone from the screwgun.
2. To remove the bit and bit holder:
a. Grab the bit holder.
b. Push it into the gear case depressing the sleeve.
c. Rotate the bit holder until the clutch engages.
d. While holding the sleeve depressed, pull the bit holder out.
NOTE: Refer to and follow all instructions on changing bits and
holders in your screwgun manual.
3. Push and rotate the provided collated screwdriving bit (H) into the
spindle until ball lock snaps in groove of the bit shank.
Page dimensions: 8.5 x 5.5
WALT cordless screwgun for
E
WALT collated screwdriver
E
Installing and Removing the Magazine
from the Screwgun (Fig. 2)
With the the nose cone removed and provided driver bit (H) installed,
push the magazine over the bit onto the screw driver until the
magazine clicks into place and ensure that it does not disengage.
FIG. 2
NOTE: make sure the screw driver control lever is set to forward
rotation before use.
To remove the magazine, press and hold the release buttons (G) on
both sides of the accessory and pull accessory off the screwgun.
OPERATION
WARNING: To reduce the risk of injury, turn unit off
and disconnect it from power source before installing and
removing accessories, before adjusting or when making
repairs. An accidental start-up can cause injury.
3
H
G

Publicité

Table des Matières
loading

Table des Matières