Ibiza Light LEDPAR-LAS Manuel D'utilisation page 3

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
IMPORTANT
The laser is sensitive to low temperatures. Please operate the laser at a room temperature of at least 18°C. If the laser
is cold, let it heat up for a while otherwise it might not work.
Specifications
Voltage: ................................................................................................................. 220-240V∼ 50/60Hz
Power consumption: .......................................................................................................................................... 25W
Light source: ........................................................................................................... 18pcs of 1W RGB LED
..........................................................................................Laser: Red 100mW, Green 30mW
Operating modes: .............. Sound control, Auto-run, Master/Slave, DMX512, Remote control
Max. Ta ................................................................................................................................. 40°C
Channel: .......................................................................................................... 8x DMX channels
Data input.................................................................................... Locking 3-pin XLR male socket
Data output ............................................................................ Locking 3-pin DMX female socket
Data pin configuration ................................................................. Pin1 shield, pin 2 (-), pin 3 (+)
Dimensions ..................................................................................................... 210 x 215 x 95mm
N.W: .................................................................................................................................... 1.2kg
SETUP
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of
channels required by all fixtures on a serial data link determines the number of fixtures that the data link can
support.
Important: Fixtures on a serial/data link must be daisy chained in one single line. Maximum recommended serial
data link distance: 500 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
To link fixtures together you must use data cables. If you choose to create your own cable, please use data-grade
cables that can carry a high quality signal and are less prone to electromagnetic interference.
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to
connect a DMX signal terminator.
CAUTION
Do not allow contact between the common and the fixture's chassis ground. Grounding the common can cause a
ground loop, and your fixture may perform erratically. Test cables with an ohm meter to check correct polarity and
to make sure the pins are not grounded or shorted to the shield or each other.
©Copyright LOTRONIC 2015
COMMON
DMX +
INPUT
DMX-
LEDPAR-LAS
Resistance 120 ohm
1/ 4w between pin 2
(DMX-) and pin 3
(DMX+) of the last
fixture.
Page 3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

15-1474

Table des Matières