Chimney Extension
Installation (optional)
Optional chimney extensions and telescoping extensions
are used to fill the space between the hood and ceiling
(available for separate purchase). Chimney extensions fill
the space between the hood and ceiling of 8' (2.4 m) and 9'
(2.7 m) ceilings. Telescoping extensions accommodate 10'
(3 m) ceilings. For dealer information, visit the Find a
Dealer section on our website at www.thermador.com.
MODEL
6" EXTENSION
HPCN36NS
CHMHP366N
HPCB36NS
CHMHP366N
HPCN48NS
CHMHP486N
HPCB48NS
CHMHP486N
Chimney Extension Installation
IMPORTANT NOTE: Secure the Chimney Hood to the wall
before installing the Chimney Extension. See "Hanging the
Chimney Hood" on page 11 before securing the actual
Extension.
1. Installation of the chimney hood should maintain a
minimum height of 30" (762 mm) from the bottom of the
hood to the cooking surface. To determine placement
of the hood with a Chimney Extension, the height of the
chimney extension must be calculated (see
"Calculating Optional Duct Cover Height" on page 9).
2. From inside of hood, screw the supplied 5/8" (16 mm)
sheet metal screws through the holes on each side and
along the front into bottom of the extension, as shown
in Figure 21. (Screw quantity is dependent on hood
size.)
1
Figure 21: Attachment of Chimney Extension to Hood
English 16
Telescoping Chimney Extension
Installation
IMPORTANT NOTE:
Secure the Chimney Hood to the wall after installing the
Extension Mounting Bracket, but before installing the
Telescoping Chimney Extension. See "Hanging the
Chimney Hood" on page 11 before securing the actual
Extension.
Securing the Telescoping Chimney Extension Bracket
12" EXTENSION
1. Ensure that the minimum height of 30" (762 mm) from
CHMHP3612N
CHMHP3612N
CHMHP4812N
2. Locate two studs at the mounting location, as shown in
CHMHP4812N
18" – 35"
18" – 35"
18" – 35"
( 457 – 889)
( 457 – 889)
( 457 – 889)
2
3. At the wall stud locations, measure
the bottom of the hood to the cooking surface will be
maintained (see "Calculating Optional Duct Cover
Height" on page 9).
Figure 22.
measurements in inches (mm)
A A
⅝" (16)
⅝" (16)
from the ceiling to the top of the bracket.
B B B
17"
17"
17"
(432)
(432)
(432)
18"
18"
18"
(457)
(457)
(457)
18" (457)
18" (457)
18" (457)
A
B
36"
14" (356)
20¾" (527)
48"
14" (356)
32⅞" (835)