5. Hook up the wire harness connector inside the bracket
to the terminal on the back side of the remote control.
Use either terminal.
6. Snap the remote control into the bracket.
Chimney extension installation
(optional)
Optional duct cover extensions and telescoping
extensions are used to fill the space between the hood
and ceiling (available for separate purchase). Chimney
extensions fill the space between the hood and ceiling of
8' (2.4 m) ceilings. Telescoping extensions accommodate
10' (3 m) ceilings.
Model
6'' extension
HPCN36WS CHMHP366W
HPCN48WS CHMHP486W
Telescoping extension
CHMHP36TW (18''– 35'')
CHMHP36XTW (42''–59'')
CHMHP48TW (18''– 35'')
CHMHP48XTW (42''–
59'')
Duct cover extension installation
IMPORTANT: Secure the chimney wall hood to the wall
before installing the chimney extension. See "Hanging the
chimney wall hood" on page 13 bef o re securing the actual
extension.
1. Installation of the chimney hood should maintain a
minimum height of 30" (762 mm) from the bottom of
the hood to the cooking surface. To determine
placement of the hood with a chimney extension, the
height of the chimney extension must be calculated
(see "Calculating the optional chimney extension
height" on page 12).
2. From inside of hood, screw the supplied 5/8'' (16 mm)
sheet metal screws through the holes on each side
and along the front into bottom of the extension, as
shown in below. (Screw quantity is dependent on
hood size.)
Telescoping chimney extension installation
IMPORTANT: Secure the Chimney Hood to the wall after
installing the Extension Mounting Bracket, but before
installing the Telescoping Chimney Extension. See
"Hanging the chimney wall hood" on page 13 before
securing the actual Extension.
Securing the telescoping chimney extension bracket
1. Ensure that the minimum height of 30" (762 mm) from
the bottom of the hood to the cooking surface will be
maintained (See "Calculating the optional chimney
extension height" on page 12 .)
18