Installation and Operating Instructions
EN
EN
m
WARNING
nm
CHAPTER 5
TECHNICAL DATA
RD.. and VD.. – Roof Fans
Error/Fault
Abnormal noises
Power consumption too
high
Fan does not perform
(speed)
4.3
Spare parts
Only original Helios spare parts are to be used. All repairs may only be carried out by authorised specialist personnel/
companies.
4.4
Standstill and disposal
m
WARNING
When dismantling, live parts can be exposed, which can result in electric shock if touched. Before dismantling,
isolate the unit from the mains power supply and protect against being switching on again!
The generally applicable safety at work and accident prevention regulations must be observed!
– Electrical work must only be carried out by an authorised electrician
– Fully isolate electrical connection from mains power supply
– Use appropriate lifting equipment and fastening devices to dismantle the fan
– Observe the instructions in the electric motor maintenance manual for decommissioning the motor
– Dispose of the fan components according to the valid rules and laws
5.0
Technical data
The product-specific technical data can be found on the type plate. The individual data is described below using an
example.
Type: VDW 200/2
e
230 V 1~
t
2430 1/min
Einsatz und Betrieb nur gemäß Instruktions-Nr.
Operation only according to instruction no.
Utilisation uniquement selon instruction no.
Character key Type plate Fan:
q Manufacturer's address
w Fan mark:
CE = CE mark
e Version:
VDW = type designation; alternating current
200 = size
/2 = pole
r Article number / Production code
t Nominal voltage / frequency
Causes
Incorrect operating point
Grinding impeller
Grinding impeller
Mechanical damage
Incorrect direction of rotation
Incorrect operating point
Grinding impeller
Bearing damage
Incorrect operating point
Incorrect voltage
Defective capacitor
Bearing damage
Contamination
Insufficient backflow
Incorrect direction of rotation
HELIOS VENTILATOREN GmbH + Co KG
Lupfenstraße 8, 78056 Villingen-Schwenningen, Germany
Art.-Nr.: 07126-001
r
50 Hz
0,56 A
y
IP44
Iso.cl. F
27 195
y Nominal current
u recorded nominal power
i max. ambient, transport media temp. at nominal operation
Nominal speed
Protection category / motor insulation class / capacitor
Weight
8
Solution
Check suitability of fan, Check/keep inflow
and outflow clear
Clean, replace if necessary
Replace bearing
Carry out maintenance
Check, modify connection
Check suitability of fan, Check/keep inflow
and outflow clear
Clean, replace if necessary
Replace bearing
Check suitability of fan, Check/keep inflow
and outflow clear
modify
Check/replace capacitor
Replace bearing
Clean
Widen backflow openings
modify
q
w
PC 06016
TN 70 °C
0,125 kW
i
u
8 kg
C 4 µF
Fig.3