Helios RR EC 100 Notice De Montage Et D'installation

Helios RR EC 100 Notice De Montage Et D'installation

Masquer les pouces Voir aussi pour RR EC 100:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Helios Ventilatoren
MONTAGE- UND BETRIEBSVORSCHRIFT
INSTALLATION AND OPERATING INSTRUCTIONS
NOTICE DE MONTAGE ET D'INSTALLATION
EC Rohrventilatoren
Centrifugal In-line EC Duct Fan
Ventilateur centrifuge de gaine EC
RR EC
DE
EN
FR

Publicité

Table des Matières
loading

Sommaire des Matières pour Helios RR EC 100

  • Page 1 Helios Ventilatoren MONTAGE- UND BETRIEBSVORSCHRIFT INSTALLATION AND OPERATING INSTRUCTIONS NOTICE DE MONTAGE ET D‘INSTALLATION EC Rohrventilatoren Centrifugal In-line EC Duct Fan Ventilateur centrifuge de gaine EC RR EC...
  • Page 2: Table Des Matières

    DEUTSCH Inhaltsverzeichnis KAPITEL 1 SICHERHEIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Seite 1 1.0 Wichtige Informationen .
  • Page 3: Wichtige Informationen

    Montage- und Betriebsvorschrift EC-Rohrventilatoren – RR EC 1 .0 Wichtige Informationen KAPITEL 1 Zur Sicherstellung einer einwandfreien Funktion und zur eigenen Sicherheit sind alle nachstehenden Vorschriften genau durchzulesen und zu beachten. SICHERHEIT Dieses Dokument ist Teil des Produktes und als solches zugänglich und dauerhaft aufzubewahren um einen sicheren Betrieb des Ventilators zu gewährleisten.
  • Page 4: Allgemeine Hinweise

    Stillstandzeiten, starke Verschmutzung, übermäßige Beanspruchung durch klimatische, technische oder elekt- ronische Einflüsse geeignet. Gleiches gilt für die mobile Verwendung der Ventilatoren (Fahr-, Flugzeuge, Schiffe, usw.). Ein Einsatz unter diesen Bedingungen ist nur mit Einsatzfreigabe seitens Helios möglich, da die Serienausführung hier- für nicht geeignet ist.
  • Page 5: Einlagerung

    Installation zu treffen. Der Motor darf keinesfalls mit Wasser beaufschlagt werden. KAPITEL 3 3 .0 RR EC Typenübersicht EC-Radialrohrventilator RR EC TECHNISCHE DATEN Baureihe RR EC 100 Best .Nr . 05804 RR EC 125 Best .Nr . 05789 RR EC 160 Best .Nr . 05785 RR EC 200 A Best .Nr .
  • Page 6: Benutzer-Wartung

    3 .1 .1 Motortypenschild Technische Daten des Motors sind dem Motortypenschild zu entnehmen! 3 .2 Zubehör Der Gebrauch von Zubehörteilen, die nicht von Helios empfohlen oder angeboten werden, ist nicht statthaft. Eventuell auftretende Schäden unterliegen nicht der Gewährleistung. Befestigungs-Verbindungsmanschette BM . .
  • Page 7: Lieferumfang/Konstruktiver Aufbau

    Montage- und Betriebsvorschrift EC-Rohrventilatoren – RR EC Alle nachfolgenden Informationen und Anweisungen sind nur für eine autorisierte Elektrofachkraft bestimmt! 6 .0 Lieferumfang/Konstruktiver Aufbau KAPITEL 6 Die Radial-Rohrventilatoren RR EC bestehen aus einem Gehäuse, einem Laufrad, einem Elektromotor und der zuge- hörigen Befestigung des Motors im Gehäuse.
  • Page 8: Elektrischer Anschluss / Inbetriebnahme

    Montage- und Betriebsvorschrift EC-Rohrventilatoren – RR EC Abb .4 Montagekonsole für Wand oder Deckenmontage Mounting rail for wall or ceiling suspension Rail support pour montage au mur ou au plafond Wand Wall ò ò 4x Bohrschrauben 4x Self-tapping screws Winkel 4x vis autoforeuses Bracket ù...
  • Page 9: Funktionsbeschreibung Rr Ec

    Widerständen, Winddruck u .a .m . abhängig ist, eingehalten werden . Der Einsatz von Fremdfabrikaten kann, vor allem bei elektronischen Geräten, zu Funktionsproblemen, Zerstörung des HINWEIS Reglers und/oder des Ventilators führen. Bei Einsatz seitens Helios nicht freigegebener Regelgeräte, entfallen Garantie- und Haftungsansprüche. Ein / Aus Schalten: Häufiges Ein und Ausschalten von EC-Ventilatoren kann über den 0-10 V Steuereingang bzw.
  • Page 10 Montage- und Betriebsvorschrift EC-Rohrventilatoren – RR EC 7 .1 .2 Anschlussschema mit Drehzahl-Potentiometer PU/A 10 – Schaltplan SS-980-1 Abb .6 SS-980-1 EC-Motor SS-979 *Potentiometer min. rotational speed potentiomètre réglage de la vitesse mini PU/A 10 Art.Nr. 1734/1735 *Potentiometer min. Drehzahl LED 1 LED display logic LED 2...
  • Page 11: Technische Daten Der Steuereingänge

    (ohne PU/A LED) (mit PU/A LED) Versorgung Versorgung Versorgung Netzgerät NG24 RR EC 100 10 V / 10 mA 0-10 V / 1,0 mA nicht möglich (Ri = 10 kOhm) 10 V / 10 mA 0-10 V / 1,0 mA nicht möglich...
  • Page 12: Reinigung

    Netzspannung prüfen Ventilator startet nicht Anschluss nach Schaltplan überprüfen – Laufrad blockiert Blockade lösen, reinigen, ggf. Laufrad ersetzen – Motor blockiert Helios Kundendienst kontaktieren Ventilator dreht nicht – Ausfall der Netzspannung Netzspannung prüfen (nicht mehr) – Temperaturüberwachung hat - Zu- und Abströmung prüfen / freihalten ausgelöst...
  • Page 13: Konformitätserklärung

    Montage- und Betriebsvorschrift EC-Rohrventilatoren – RR EC Bauteile und Komponenten des Ventilators, die ihre Lebensdauer erreicht haben, z.B. durch Verschleiß, Korrosion, mechanische Belastung, Ermüdung und / oder durch andere, nicht unmittelbar erkennbare Einwirkungen, sind nach erfolgter Demontage entsprechend den nationalen und internationalen Gesetzen und Vorschriften fach- und sachge. recht zu entsorgen.
  • Page 14 ENGLISH Table of Contents CHAPTER 1 SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1 1.0 Important information .
  • Page 15: Important Information

    Installation and Operating Instructions Centrifugal In-line EC Duct Fans – RR EC 1 .0 Important information CHAPTER 1 In order to ensure complete and effective operation and for your own safety, all of the following instructions should be read carefully and observed. SAFETY This document should be regarded as part of the product and as such should be kept accessible and durable to ensure the safe operation of the fan.
  • Page 16: Area Of Application

    All versions of this documentation must be observed, otherwise the warranty shall cease to apply. The same applies to liability claims against Helios. The use of accessory parts, which are not recommended or offered by Helios, is not GENERAL INFORMATION permitted.
  • Page 17: Receipt

    CHAPTER 3 3 .0 RR EC type overview Centrifugal in-line EC fan RR EC TECHNICAL DATA Series RR EC 100 Ref . no . 05804 RR EC 125 Ref . no . 05789 RR EC 160 Ref . no . 05785 RR EC 200 A Ref .
  • Page 18: Motor Type Plate

    Technical data about the motor can be found on the motor type plate! 3 .2 Accessories The use of accessories not offered or recommended by Helios is not permitted. Any potential damage is not covered by warranty. Pipe clamp connectors BM .
  • Page 19: Scope Of Delivery/Design

    Installation and Operating Instructions Centrifugal In-line EC Duct Fans – RR EC All of the following information and instructions are intended solely for authorised electricians! 6 .0 Scope of delivery/Design CHAPTER 6 The centrifugal in-line fans RR EC consist of a casing, impeller, electric motor and the associated mounting of the motor in the casing.
  • Page 20: Electrical Connection / Commissioning

    Installation and Operating Instructions Centrifugal In-line EC Duct Fans – RR EC Fig .4 Montagekonsole für Wand oder Deckenmontage Mounting rail for wall or ceiling suspension Rail support pour montage au mur ou au plafond Wand Wall ò ò 4x Bohrschrauben 4x Self-tapping screws Winkel 4x vis autoforeuses...
  • Page 21: Functional Description Rr Ec

    The use of other brands, especially other electronic devices, can lead to malfunctioning and even destruction of the NOTE controller or fan. Controllers which have not been cleared by Helios are not liable for warranty and guarantee claims. Activation / deactivation: EC fans can be frequently activated and deactivated via the 0-10 V control input or the release input depending on the type.
  • Page 22 Installation and Operating Instructions Centrifugal In-line EC Duct Fans – RR EC 7 .1 .2 Wiring diagram SS-980-1 - Wiring diagram with speed-potentiometer PU/A 10 Fig .6 SS-980-1 EC-Motor SS-979 *Potentiometer min. rotational speed potentiomètre réglage de la vitesse mini PU/A 10 Art.Nr.
  • Page 23: Technical Data For Control Inputs

    EUR EC fan supply with external pow- LED) LED) supply er supply NG24 RR EC 100 10 V / 10 mA 0-10 V / 1,0 mA not possible (Ri = 10 kOhm) RR EC 125 10 V / 10 mA...
  • Page 24: Cleaning

    Fan does not start Check connection according to wiring diagram – Impeller blocked Clear blockage, clean, replace if necessary – Motor blocked Contact Helios customer services Fan does not turn – Mains voltage failure Check mains voltage (no longer turns) –...
  • Page 25: Declaration Of Conformity

    Installation and Operating Instructions Centrifugal In-line EC Duct Fans – RR EC Parts and components of the fan, whose service life has expired, e.g. due to wear and tear, corrosion, mechanical load, fatigue and/or other effects that cannot be directly discerned, must be disposed of expertly and properly after dis- assembly in accordance with the national and international laws and regulations.
  • Page 26 FRANÇAIS Sommaire CHAPITRE 1 SÉCURITÉ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1 1.0 Informations importantes .
  • Page 27: Informations Importantes

    1 .2 Consignes de sécurité DANGER Des dispositions particulières sont applicables pour l’utilisation, le raccordement et le fonctionnement ; contacter Helios en cas de doute. Veiller à bien respecter les normes nationales, règlements de sécurité et instructions. Lunettes de protection Empêchent toute blessure oculaire.
  • Page 28: Chapitre 2 Informations Générales

    à des contraintes techniques et électroniques, une demande d’approbation est requise par Helios, les modèles de série n’étant pas prévus pour cet usage. IIl en est de même pour l'utilisation de ces ventilateurs en mouvement (voitures, avions, bateaux, etc...). Une utilisation dans ces conditions est soumise à l'autorisation d'He- lios, étant donné...
  • Page 29: Réception De La Marchandise

    En cas de réexpédition (longues distances, voies maritimes, etc.), vérifier que l’emballage est bien approprié aux conditions de transport. Les dommages dus à de mauvaises conditions de transport ou de stockage, à une utilisa- tion anormale sont sujets à vérification et contrôle et entraînent la suppression de la garantie Helios. 2 .5 Performances La plaque signalétique du moteur indique la puissance électrique requise ;...
  • Page 30: Chapitre 4 Fonctionnalites

    Système de gaine : L’ensemble des composants Helios correspond aux normes de diamètres de gaine standards. Elles peuvent être en tôle d’acier, en aluminium flexible, en synthétique, etc. Il faut veiller aux normes de sécurité lorsqu’il y a plus de deux niveaux.
  • Page 31: Chapitre 6 Installation

    Notice de montage et d'utilisation EC - Ventilateurs centrifuges de gaine – RR EC Toutes les informations et consignes suivantes ne sont destinées qu’à un électricien habilité ! 6 .0 Contenu de la livraison / Détails de l’installation CHAPITRE 6 Les ventilateurs centrifuges de gaine RR EC sont composés d’une enveloppe, d’une turbine, d’un moteur électrique et de moyens de fixation du moteur à...
  • Page 32: Raccordement Électrique / Mise En Service

    Notice de montage et d'utilisation EC - Ventilateurs centrifuges de gaine – RR EC Fig . 4 Montagekonsole für Wand oder Deckenmontage Mounting rail for wall or ceiling suspension Rail support pour montage au mur ou au plafond Wand Wall ò...
  • Page 33: Fonctionnalités Pour L'installateur

    L’utilisation d'un appareil de commande d’un autre fabricant peut conduire à des problèmes de fonctionnement de la REMARQUE régulation et/ou du ventilateur. Lors de l’utilisation d’une régulation non conseillée par Helios, la garantie et les réserves constructeur s’annulent. Commutation : Les ventilateurs EC peuvent être fréquemment mis en route ou arrêtés par le biais du signal 0-10 V ou via l'entrée d'au-...
  • Page 34 Notice de montage et d'utilisation EC - Ventilateurs centrifuges de gaine – RR EC 7 .1 .2 Schéma de raccordement SS-980-1 - avec potentiomètre de vitesse PU/A 10 Fig .6 SS-980-1 EC-Motor SS-979 *Potentiometer min. rotational speed potentiomètre réglage de la vitesse mini PU/A 10 Art.Nr.
  • Page 35: Maintenance Et Entretien

    (avec LED PU/A) Ventilateur EUR EC Ventilateur externe NG 24 V / A (charge) RR EC 100 10 V / 10 mA 0-10 V / 1,0 mA impossible (Ri = 10 kOhm) 10 V / 10 mA 0-10 V / 1,0 mA...
  • Page 36: Entretien

    Notice de montage et d'utilisation EC - Ventilateurs centrifuges de gaine – RR EC m L'accès au boitier de raccordement n'est autorisé qu'après coupure de l'alimentation et respect d'un délais AVERTISSEMENT d'attente de 5 minutes . m AVERTISSEMENT Les parties rotatives de l’hélice peuvent pincer vos doigts . Avant tous travaux d’entretien ou de maintenance, l’appareil doit être mis hors-tension et protégé...
  • Page 37: Chapitre 9 Déclaration De Conformité

    Notice de montage et d'utilisation EC - Ventilateurs centrifuges de gaine – RR EC Les pièces, composants et matériel démonté arrivés en fin de vie (usure, corrosion, dégradation, etc.), sans consé- quences nuisibles immédiates, sont à recycler selon les normes et règlementations nationales et internationales. Idem pour les produits consommables (huile, graisse, etc.).
  • Page 38 Notice de montage et d'utilisation EC - Ventilateurs centrifuges de gaine – RR EC...
  • Page 39 Notice de montage et d'utilisation EC - Ventilateurs centrifuges de gaine – RR EC...
  • Page 40 Service / Information HELIOS Ventilatoren GmbH & Co · Lupfenstraße 8 · 78056 VS-Schwenningen HELIOS Ventilateurs · Le Carré des Aviateurs · 157 av. Charles Floquet · 93155 Le Blanc Mesnil Cedex CH HELIOS Ventilatoren AG · Tannstrasse 4 · 8112 Otelfingen GB HELIOS Ventilation Systems Ltd.