Troubleshooting; Spray Gun; Air Motor - Titan PowrCoat Série Mode D'emploi

Masquer les pouces Voir aussi pour PowrCoat Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.

Troubleshooting

7.1

Spray Gun

Problem
A.
Spitting gun
B.
Gun will not shut off
C.
Gun does not spray
D.
Insufficient material supply.
E.
Poor spraying pattern.
7.2

Air Motor

Problem
A.
Motor stops at top or bottom
of stroke - air does not exhaust
when gun is open.
B.
Motor stops, blows air from
exhaust when gun is open.
PowrCoat
Cause
1.
Air in system
2.
Dirty gun
3.
Needle assembly out of adjustment
4.
Broken or chipped seat
1.
Worn or broken needle & seat
2.
Needle assembly out of adjustment
3.
Dirty gun
1.
No paint
2.
Plugged filter or tip
3.
Broken needle in gun
1.
Material pressure set too low.
2.
Blocked spray gun filter or pump high
pressure filter.
3.
Tip is blocked.
4.
Tip is too small.
1.
Tip is too large.
2.
Material pressure at the pump is set too
low.
3.
Material viscosity is too high.
4.
Worn tip.
Cause
1.
Piston rod is loose where it connects to the
fluid section.
2.
Trip springs or valve spring broken.
3.
Motor is frozen due to icing or lack of
lubrication.
1.
See above.
2.
Air valve is in dead stall position.
3.
O-rings were worn or damaged.
GB
Solution
1.
Inspect connections for air leaks.
2.
Disassemble and clean.
3.
Inspect and adjust.
4.
Inspect and replace.
1.
Replace.
2.
Adjust.
3.
Clean.
1.
Check fluid supply.
2.
Clean.
3.
Replace.
1.
Increase the material pressure at pump.
2.
Clean or replace the gun filter and/or pump high
pressure filter.
3.
Clean the tip.
4.
Select a larger tip.
1.
Select a smaller tip.
2.
Increase the material pressure at the pump.
3.
Dilute the material according to the material
manufacturer's instructions.
4.
Replace with a new tip.
Solution
1.
Tighten connection.
2.
Inspect and replace where neessary.
3.
Check the Air-Care™ fluid level in the Automatic
Lubricator. If low, add Air-Care™ to reservoir.
If condition persists, check air supply for
contamination.
1.
See above.
2.
Remove one trip spring retainer, trip spring and ball.
Push spool valve up or down, lubricate, reassemble
and restart.
3.
Install minor service kit and follow instructions in
Servicing section of manual.
If dust or dirt is found inside motor, check air supply for
contamination.
15
Troubleshooting

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

05331045c05331064c05331072c05331045w05331064w05331072w

Table des Matières