8. Make sure the sprayer is earthed (grounded). All sprayers are
equipped with a earthing (grounding) cable (1). Clip the end
of the grounding cable to a true earth ground.
9. Strain all paints with a nylon strainer to ensure trouble free
operation and freedom from frequent cleaning of the inlet
screen and gun filter.
10. Make sure the spray area is well ventilated to prevent
hazardous operation with volatile solvents or exhaust fumes.
If lacquer or other flammable materials are to be
sprayed, ALWAYS locate the compressor outside the
immediate spraying area. Failure to do so may cause
an explosion.
11. Locate the compressor outside the immediate spraying area
to avoid clogged air intake of the compressor with overspray.
4.2

Automatic Lubricator

The automatic lubricator (Fig. 10, item 1) provides lubrication to the
air that is being delivered to the system. It is set at the factory for the
correct injection rate and should not be adjusted until the reservoir
needs to be refilled with AirCare™ lubricant. Check the level through
the openings (2) in the side of the air motor shroud.
After refilling the reservoir, the automatic lubricator will need
adjusting. Turn the adjusting screw (1) clockwise to increase the
AirCare™ injection rate and counterclockwise to decrease it.
1
2
Check the injection rate by observing the flow through the openings
in the side of the air motor shroud.
• The proper flow rate is 1 drop of AirCare™ per minute.
• In humid weather when icing may occur, increase the
injection rate.
• The injection rate comes pre-set to 1 drop / 30 sec.
PowrCoat
1
GB
4.3

Preparing a New Sprayer

If this unit is new, it is shipped with test fluid in the fluid section to
prevent corrosion during shipment and storage. This fluid must be
thoroughly cleaned out of the system with cleaning agent before you
begin spraying.
Always keep the trigger lock on the spray gun in the
locked position while preparing the system.
Attention
1. Place the siphon tube into a container of mineral spirits.
2. Place a metal container under the bleed hose.
3. Close the shutoff valve (fig. 11, item 1). The figure shows the
handle in the closed position.
4. Turn on the air compressor.
5. Turn the air regulator (2) fully counterclockwise to its lowest
pressure setting.
6. Open the bleed valve (3) by turning it fully counterclockwise.
The bleed valve handle should be pointing down.
7. Open the shutoff valve (1). The handle should now be in line
with the valve.
8. Turn the air regulator (2) clockwise to increase pressure until
the sprayer cycles evenly and solvent flows freely from the
bleed hose.
9. Allow the sprayer to run for 15–30 seconds to flush the test
fluid out through the bleed hose and into the waste container.
10. Turn off the sprayer.
a.
Turn the air regulator fully counterclockwise to its lowest
pressure setting.
b.
Close the shutoff valve.
9