Environmental Protection; Symbols Used In These Instructions; Operating The Unit; Product Information - Maico EALT 6 Instructions De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN │ 1. Safety instructions
The terminal box cover must be
correctly fitted, so that the
surrounding sealing has close
contact all the way around the
terminal box

2. Environmental protection

The unit and the packaging contain parts that
can be recycled, and should not end up in the
domestic waste.
Unpack the unit. Please dispose of the
packaging material in an environmentally-
friendly way in compliance with the regu-
lations valid in the country where you are.
3. Symbols used in these
instructions
Direct risk of danger. Failure to
observe will result in severe
injury or death.
DANGER
Possible situation which could
NOTICE
cause damage to the product or
its surroundings.
INFO symbol indicating
important information and tips.
Bullet point for information on the
respective subject.
Instructions. Follow the
1.
instructions given in the order
stated.
12

4. Operating the unit

The EALT 6 is switched on and off with the
operating mode switch [1]. Units connected to
the EALT 6 can be operated in automatic or
continuous operating mode.
Automatik (Automatic Mode)
● In "automatic controlled operation"
operating mode, the EALT 6 is controlled
by the controller. All fans are switched on
and off according to the EAT 6... setting.
MANUAL switch [3] is located in the
leftmost position. Fans connected to the
EALT 6 run in the MIN and MAX set speed
range, independent of the speed set on
the controller.
● In the "automatic manual" operating
mode, the fans which are connected to the
EALT 6, are controlled according to the
manual setting. MANUAL switch [3] is
located in the rightmost position. The fans
connected to the EALT 6 run at the speed
set with the rotary knob [8].
Dauer (Duration)
Power level. Fans connected to the EALT 6
run with maximum speed.

5. Product information

● EALT 6 with Plexiglass cover, snap-fit
fastener and lateral catch.
● Rotary knob MIN [2]: Potentiometer
minimum fan voltage, delivery condition
approx. 70 V.
● Rotary knob MAX [4]: Potentiometer
maximum fan voltage, delivery condition
approx. 230 V.
● Fan speed [8] rotary knob for speed
control of fans connected to the EALT 6,
setting range 70 ... 230 V.
● It is possible to connect several power
modules via the same external conductor.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Eat 6 g/1Eat 6 tg

Table des Matières