Bourgeat Trans'therm 10GN1/1 Notice D'utilisation Et D'entretien page 16

Fours de remise et maintien de temperature
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 7
OPERATION
y Portions trays must be placed on supports:
- for portions trays with a maximum height of 55 mm, use standard GN1/2, 1/1 or 2/1 grilles, depending on the model
- for portions trays whose height is greater than 55mm, use the "support plate for trays of height 65mm".
y Pans GN1/2 (cabinet 5GN1/2) or GN1/1 (other models) can be placed directly on the slides in the formed walls or slides in the trol-
leys (depending on model). Supports must be used for trays of smaller dimensions:
Slide cabinets :
- standard grilles for trays with a maximum height of 55 mm
- support plates for trays of height 65 mm
Trolley cabinets :
- standard grilles for trays with a maximum height of 65 mm
y When the cabinet is used for the first time, set the cabinet to 165°C, open the vent and run for 1 hour to ensure that any grease
remaining on internal panels is completely burned off.
y Start up the appliance by pressing T1
y Select heating mode by pressing T2
y Preheat the appliance (approximately 20 minutes)
y Trolley cabinets :
- place the products on the trolley.
- open the door and insert the trolley.
y Slide cabinets :
- open the door.
- put the products in position
y Close the door.
y Press T6 if you wish to use humidification.
Operation using the timer :
y Set the timer
y After 10 seconds the timer is locked and the timer countdown starts.
y When the timer reaches zero, the cabinet automatically switches over to the temperature hold (indicator lights V1 and V2 off) posi-
tion and an alarm sounds for 10 seconds.
After a few minutes your cabinet will stabilise at the holding temperature. It is not necessary to use the timer.
If you do not want to use a holding temperature you can then take out the trays or baskets For another bring to temperature cycle,
stop the cabinet by pressing T1. Press T1 once again for another cycle.
Operation with the probe (option) :
y Take the probe from its support.
y Insert it in a tray or basket.
y Close the door.
y Press key T3. The temperature of the insertion probe is displayed. If the probe temperature reading is greater then 70°, an alarm
sounds. Deactivate the insertion probe by pressing key T3. Wait a few seconds and press T3 once again.
y When the products have reached the desired temperature, the cabinet automatically switches over to the temperature-hold posi-
tion (indicator lights V1 and V2 go off) and an alarm sounds for 10 seconds.
After a few minutes your cabinet will stabilise at the holding temperature. It is not necessary to use the timer.
If you do not want to use a holding temperature you can then take out the trays or baskets For another bring to temperature cycle,
stop the cabinet by pressing T1. Press T1 once again for another cycle.
For direct use in temperature holding, the products must be inserted at a temperature above 63°C. In this case, the stick-in sensor :
- start the cupboard by pressing T1.
- press T5. The display flashes on «00».
- after 10 seconds, the timer is blocked. The cupboard stabilizes at the holding temperature after 10 mn preheating.
- load the cupboard as indicated in the «Reheating» chapter.
TRACEABILITY (OPTION)
Recording Data
y Your cabinet must be equipped with the traceability option.
y The recording capacity is 260 hours, with one recording per minute. That is, for example, 43 days with an average daily usage of 6
hours.
y Recording starts automatically once your cabinet is switched on. When the memory is full, the message "FUL" is displayed on the
display D.
y Depending on whether the timer or insertion probe is in use, the recorded temperature will be that of the enclosure (timer) or that
of the insertion probe.
Data transfer
y Transfer is carried out using the USB connector located on the top right hand side of the cabinet. In order to guarantee proper
operation, use only the USB traceability key marked Bourgeat and supplied with the traceability module :
- Press T1
- fit a USB key into the connector
- keep T3 pressed until the message "USB" is displayed on the display D. This will flash during transfer. On completion the board
memory is empty and you may remove the key.
16
INTRODUCTION OF THE PRODUCTS
USE IN REHEATING
USE IN TEMPERATURE HOLDING

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Trans'therm 15gn1/1Trans'therm 20gn1/1Trans'therm 10gn2/1

Table des Matières