INSTRUCTIONS FOR USE OF CONTROL PANEL
Display
D
Time display (when using the timer) or Probe temperature display (when using temperature probe)
V1
Reheating indicator
V2
Reheating indicator for fried products
V3
Temperature probe indicator (option)
V4
Humidifier indicator
P1
Operating light with the timer
P2
Operating light with the insertion probe (option)
Controls
T1
Main run/stop key
T2
Temperature setting button
T3
Insertion probe (option) and USB (option) key
T4
Temperature timing increase key
T5
Temperature timing decrease key
T6
Humidification run / stop key
y Start -up :
- press key T1
- lights V1 and P1 come on
- the value "0" is displayed at D
y Settings
Selecting heating mode :
- when indicator light V1 is lit this shows that the cabinet is in the "Bring to temperature» position.
- when indicator light V2 is lit this shows that the cabinet is in the "Bring fried product to temperature» position.
- when indicator lights V1 and V2 are off this indicates that the cabinet is in the "Hold" position. Switchover to Hold occurs auto-
matically at the end of the 'bring to temperature' cycle.
- Press T2 to select heating mode. Each time T2 is pressed, the heating mode is changed. In case of error, continue to press until
you have returned to the desired position.
Use without temperature sensor. Timer setting.
- In the "Bring to temperature" position (indicator light V1 lit), the timer adjustment range is from 0 to 60 minutes.
- In the reheating fried products mode (indicator light V2 lit) the timer can be set from 0 to 75 minutes.
The timer is set by pressing keys T4 and T5 :
- pressing T4 increases the value
- pressing T5 decreases the value
Once one of these two keys has been pressed, the indicator light V1 or V2 and the display D begin to flash. You have 10 seconds in
which to set the timer value. After 10 seconds the indicator light and display stop flashing. The timer value is set and the countdown
commences. If you discover that you have made an error in setting, switch off the cabinet and re-start it immediately by pressing
T1. You can then re-set the timer again.
Operation with the insertion probe
Your cabinet must be equipped with the insertion probe option.
The timer is not used.
- Press key T3. The insertion probe temperature is shown on the display D. Indicator light P1 goes off and P2 comes on.
- The indicator lights V1 or V2, and V3 flash.
- The display D flashes.
- After 10 seconds the indicator lights and display stop flashing.
If you wish to continue operation without the insertion probe, switch off the cabinet and re-start it immediately by pressing T1. You
will then be able to operate once more using the timer.