y Supplied by a H07RNF cable supplied.
y The appliance is to be connected:
- to an omnipolar switch between the appliance and the electric grid, with a minimum distance of 3 mm between the contacts for
each pole.
- under the control of a high sensitivity separator and with a protection against power surges.
- to an efficient earthing device conforming to norms in force.
- to an equipotential earthing conductor not supplied with the equipment, to be connected to the 5 mm welded nut on the lower
part close to the
symbol (fixed models).
y To connect the trolley to an energy optimiser:
- remove the back door
- remove the adhesive and the cut-out located on the rear left portion,
- assemble a cable gland, a control cable connected to a contact of the optimiser, and modify the wiring of the trolley as herein-
below:
* A: original wiring
* B: modified wiring
* CEX: contact of the optimiser
- Trolleys 7 / 10 / 15 / 20GN :
- Trolley 5GN :
- Remove the back door,
- The connection is not possible for the 5GN1/2 trolley.
y The humidifier must be supplied with softened water. The water must have the following characteristics :
- hardness between 3° and 6°TH
- a PH higher than 7.5
- a chlorine level lower than 30ppm
y Fixed cabinet :
- Connect the cabinet to the water supply with a shut-off valve between the cabinet and the water pipework. Diameter of the supply
connections 1/2'' (15/21).
- Water pressure between 150 and 500 kPa (1.5 to 5 bar).
y Mobile cabinet :
- Fill the reservoir: the reservoir is located on the left-hand side part of the cabinet, between the two wheels. To fill it, pull it
towards you.
- An end stop on its support ensures that it is in its filling position. Remove the plug.
- The reservoir has a capacity of 3 litres, providing a minimum operating period of 16 hours.
- After filling, screw in the plug and push the reservoir beneath the cabinet.
14