Table des matières

Recommandations générales ........................................................................... 5
Composants fournis par l'installateur ............................................................ 6
FWD
Power supply
Capacities
Câblage d'interconnexion ................................................................................. 6
Heating capacity on water (2)
Commande de la pompe à eau glacée .......................................................................... 6
Fan motor
Pompe double d'avance/retard ...................................................................................... 6
Fan power input (3)
Current amps (3)
Start-up amps
Air flow
Relais programmables ..................................................................................... 7
minimum
nominal
maximum
Main coil
Attribution des relais à l'aide de ...................................................................... 8
Water entering/leaving connections
Tracer™ TU ....................................................................................................................... 8
Electric heater (accessory for blower only)
Electric power supply
Heating capacity
Câblage basse tension ..................................................................................... 9
Hot water coil (accessory for blower only)
Heating capacity (4)
Arrêt d'urgence ................................................................................................................ 9
G2 filter (filter box accessory)
Quantity
Marche/Arrêt externe ...................................................................................................... 9
Dimensions ( LxWxth)
G4 filter (filter box accessory)
Quantity
Fabrication de glace (en option) ....................................................................... 9
Water flow - lift height
Point de consigne eau glacée externe (ECWS) ............................................................11
Sound power level (5)
Unit dimensions
Point de consigne de limite d'intensité absorbée externe (ECLS)............................. 12
Width x Depth
Height
Détails sur le câblage du signal analogique en entrée du ECWS et ECLS ............... 13
Shipped unit dimensions
Décalage point de consigne eau glacée (CWR) ............................................ 14
Protocole de communication intelligent ...................................................... 17
Unit with electric heater (gI)
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
Interface LonTalk™ (LCI-C) ............................................................................................ 17
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
Interface BACnet (BCNT) ............................................................................................... 17
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Certification du Laboratoire d'essai BACnet (BTL) ..................................................... 17
Heat exchanger operating limits:
Interface Modbus RTU .................................................................................................. 17
FWD:
*water temperature: max 100° C
Accessories - Hot water coil:
et LonTalk ......................................................................................................... 18
*absolute service pressure: min 1 bar/max 11 bars
Protocole de communication intelligent .................................................................... 18
Sélecteurs rotatifs ......................................................................................................... 18
Description et fonctionnement des LED ..................................................................... 19
Interface de l'opérateur Tracer TD7 ................................................................. 20
Tracer™ TU ....................................................................................................... 21
4
2
© 2016 Trane
Technical Data
08
(V/Ph/Hz)
5,2
(kW)
6,3
(type)
(kW)
0,23
(A)
1,1
(A)
3,2
(m
/h)
490
3
(m
/h)
820
3
(m
/h)
980
3
(type)
(Dia)
3/4"
(V/Ph/Hz)
230/1/50
(kW)
2/4
(kW)
6,3
2
(mm)
386x221x8
-
(mm)
-
(type)
(l/h - mm)
(dB(A))
36/40/43
(dB(A))
46/50/53
(mm)
890 x 600
(mm)
250
(mm)
933 x 644
(mm)
260
(kg)
32
(A)
8/16
(A)
16 (2kW),25 (4kW)
12
20
230/1/50
8,3
15
11,9
18,9
0,46
0,65
2,2
3,1
5,5
9,3
980
1400
1650
2300
1970
2600
ISO R7 rotating female
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
8
10
12
17,4
2
2
486x271x8
586x321x8
2
2
486x264x48
586x314x48
Centrifugal
24 - 500
38/41/44
46/50/53
48/51/54
56/60/63
1290 x 820
300
350
310
360
46
61
galvanised steel
8/16
8/16
40 (230V),3*16 (400V)
3*20
30
45
18,8
30,1
20,9
38,2
1,04
1,51
4,7
5,5
14,1
16,5
1800
2700
3000
4500
3600
5400
1 1/2"
1 1/2"
400/3/50
400/3/50
12
12
22,4
34,5
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
450
650
1333 x 1008
1333*1133
460
660
76
118
8/25
8/25
3*25
3*25