Maintenance
Cleaning and disinfecting
All parts of the equipment should be cleaned after use.
Recommended cleaning products:
• Curacid PSA Rinse – For manual cleaning
• Curacid PSA Ultra – For disinfection
• Curacid PSA TC – For cleaning and disinfection in machine
Follow the instructions supplied with the cleaning products.
Maximum washing temperatur is 50°C.
Maximum drying temperature is 55°C, do not exceed 2 hours drying time.
Local requirements might stipulate extended cleaning and/or disinfection to be
performed.
Face mask
1.
Remove the breathing valve from the mask.
2.
Clean / disinfect the mask complete and rinse thoroughly in clean water to
remove all detergent residues.
3.
Shake out remaining water from the mask and dry the parts thoroughly.
Face mask - extended cleaning and disinfection
1.
Remove the breathing valve from the mask.
Respire N
13